Preparing A Fabric Interconnect For Removal - Cisco UCS 6248 UP Installation Manual

Ucs 6200 series fabric interconnect hardware
Hide thumbs Also See for UCS 6248 UP:
Table of Contents

Advertisement

Installing the Cisco UCS 6200 Series Fabric Interconnect
Step 6
Place the fan module into the front chassis cavity so it rests on the chassis, and then push the fan module into
the chassis as far as it can go and the captive screw makes contact with the chassis, and tighten the captive
screw.
Step 7
Listen for the fans if the system is powered on. You should immediately hear them operating. If you do not
hear them, ensure that the fan module is inserted completely in the chassis and the faceplate is flush with the
outside surface of the chassis.
Step 8
Verify that the LED is green. If the LED is not green, one or more fans are faulty. If this occurs, contact your
customer service representative for a replacement part.
Note

Preparing a Fabric Interconnect for Removal

Removing a standby fabric interconnect is non-disruptive in a redundant Cisco UCS configuration. Removing
an active fabric interconnect will cause the standby fabric interconnect to become active with minimal or no
disruption.
Be aware that if you remove both the active and standby fabric interconnect, or the sole fabric interconnect
from a standalone system, you are shutting down the entire Cisco UCS domain.
Procedure
Step 1
Use Cisco UCS Manager to perform the following tasks:
a) Back up your Cisco UCS Manager configuration.
b) Shut down the OS on all servers in the Cisco UCS domain.
c) Disable the Smart Call Home feature in the Cisco UCS domain.
d) Decommission every attached chassis in the Cisco UCS domain.
For details, see the Configuration Guide for the version of Cisco UCS Manager that you are using. The
configuration guides are available at the following URL:
http://www.cisco.com/en/US/products/ps10281/products_installation_and_configuration_guides_list.html
Step 2
Power down every attached chassis as described in the
Guide.
When powering down and removing clustered fabric interconnects, remove the secondary first, and then
remove the primary.
OL-24475-03
If you purchased this product through a Cisco reseller, contact the reseller directly for technical
support. If you purchased this product directly from Cisco, contact Cisco Technical Support at this
URL:
http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html.
Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide
Preparing a Fabric Interconnect for Removal
Cisco UCS 5108 Server Chassis Hardware Installation