System Hardware Best Practices; Installation Best Practices; Initialization Best Practices; System Operation Best Practices - Cisco UCS 6248 UP Installation Manual

Ucs 6200 series fabric interconnect hardware
Hide thumbs Also See for UCS 6248 UP:
Table of Contents

Advertisement

System Hardware Best Practices

• When a port has a Link Down status, it checks if an SFP is inserted.
• If an SFP is inserted, the port status remains at Link Down, and the F0276 event is not cleared. This
• If there is no SFP detected, the port status transitions from Link Down status to SFP Not Present. This
• When the port status is no longer Link Down, the F0276 is cleared.
System Hardware Best Practices

Installation Best Practices

When installing the chassis, follow these best practices:
• Plan your site configuration and prepare the site before installing the chassis.
• Verify that you have the appropriate power supplies for your chassis configuration.
• Install the chassis following the rack and airflow guidelines presented in this guide.
• Verify that the chassis is adequately grounded.

Initialization Best Practices

When the initial system boot is complete, verify the following:
• Power supplies are supplying power to the system.
• Fan modules are operating normally.
• The system software boots successfully.

System Operation Best Practices

To ensure proper operation of your system, take the following actions:
• Make a copy of the running configuration to CompactFlash for a safe backup.
• Never use the init system CLI command unless you understand that you will lose the running and startup
Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide
88
situation occurs when the SFP cable is plugged into the Fabric Interconnect port, and the SFP at the I/O
module is disconnected.
The "Link down or not connected" fault appears, and the fault is not cleared until the SFP is plugged
back into the I/O module port.
situation occurs when the SFP is plugged into the I/O module and the other end is not plugged into the
Fabric Interconnect port that is configured to be the server.
configuration as well as the files stored on bootflash:.
Troubleshooting Hardware Components