Danfoss FC 300 Operating Instructions Manual page 70

Vlt automationdrive 0.25-75 kw
Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

Specifications
High/Normal Load
Typical Shaft Output [kW]
Enclosure IP20
Enclosure IP21
Enclosure IP55, IP66
Output current
Continuous (3x200-240 V) [A]
Intermittent
(60 s overload)
(3x200-240 V) [A]
Continuous kVA (208 V AC) [kVA]
Max. input current
Continuous (3x200-240 V) [A]
Intermittent
(60 s overload)
(3x200-240 V) [A]
Additional specifications
IP20 max. cable cross-section
(mains, brake, motor and load
sharing)
IP21, IP55, IP66 max. cable cross-
5)
section
(mains, motor) [mm
2)
(AWG)]
IP21, IP55, IP66 max. cable cross-
section
5)
(brake, load sharing)
[mm
2
(AWG)]
Max cable size with mains
disconnect [mm
10
10
Estimated power loss
at rated max. load [W]
Weight, enclosure IP21, IP55/IP66
[kg]
Efficiency
4)
Table 10.3 Mains Supply 3x200-240 V AC
For fuse ratings, see 10.3.1 Fuses
1) High overload = 160% torque during 60 s. Normal overload = 110% torque during 60 s.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within
cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the
frequency converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to 30 W to the losses.
(Though typical only 4 W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (
5) The three values for the max. cable cross section are for single core, flexible wire and flexible wire with sleeve, respectively.
66
P15K
1)
HO
15
B4
C1
C1
59.4
89.1
21.4
54
81
5)
35 (2)
2
50 (1)
50 (1)
2)
2
2)
(AWG)]
624
4)
45
0.96
MG33AM02 - VLT
VLT
®
AutomationDrive Operating
Instructions
P18K
NO
HO
NO
HO
18.5
18.5
22
22
C3
C1
C1
74.8
74.8
88
88
82.3
112
96.8
132
26.9
26.9
31.7
31.7
68
68
80
80
74.8
102
88
120
50 (1)
50 (1)
50 (1)
50, 35, 35 (1, 2, 2)
737
740
845
874
45
0.97
®
is a registered Danfoss trademark
P22K
P30K
NO
HO
NO
30
30
37
C3
C4
C1
C2
C1
C2
115
115
143
127
173
157
41.4
41.4
51.5
104
104
130
114
156
143
50 (1)
150 (300MCM)
50 (1)
150 (300MCM)
50 (1)
95 (3/0)
95, 70, 70
(3/0, 2/0, 2/0)
1140
1143
1353
45
65
0.97
0.97
± 15% (tolerence relates to variety in voltage and
P37K
HO
NO
37
45
C4
C2
C2
143
170
215
187
51.5
61.2
130
154
195
169
150 (300MCM)
150 (300MCM)
95 (3/0)
185, 150, 120
(350MCM,
300MCM, 4/0)
1400
1636
65
0.97
± 5%).