FS730
Information Sheet for Builders and Architects
Appliance Information
Product Dimensions
All outside dimensions taken from the appliance are
with the standoffs attached.
735mm*
505mm
368mm*
368mm*
753mm
For further information or specifications, visit the
technical section of our website www.escea.com
to view the latest product Installation Manual.

Specifications

Heat Output
5-5.6 kW
Star Rating
3-4 stars
Gas Input/Consumption 22-25 MJ/hr
Gas Connection
lower right, 1/2" BSP female thread
Gas Type
Natural Gas / ULPG (NZ) / Propane (Aus)
Weight
45 kg
Room fan
Yes
Flue Type
Simpson Duravent Direct Vent (False Chimney)
Flexi Flue (Masonry)
Flue Size
6" mm Outer, 4" mm Inner (Direct Vent)
4" and 3" Flexi Flue (Masonry)
Power Requirement
3 pin earthed 230V power outlet +isolating switch
to be within 1.0m of rear right hand corner of the
appliance.
Smart Heat App
Yes
124mm
381mm
*Not including Lid

Flue Installation

The freestanding unit and flue system
should be installed prior to the AF-
Series fireplace being installed.
□ Place the freestanding unit in the
correct location, complying with
the clearances specified in the previous
section.
□ Remove 2 screws on each side of
the fascia just below the top panel and
pull towards you to remove the fascia.
□ Each corner of the FS730 has
securing holes to fix the FS730 to the
floor.
□ Refer to section C of this instal-
lation manual for minimum and max-
imum flue lengths, restrictor settings
for your installation, and all other flue
information.
□ Run the black Ø230mm flue
liner lengths from the top of the
freestanding unit until it penetrates the
Ø265mm ceiling hole.
□ Use the supplied Ceiling plate for
tidying the internal termination point
of the Ø230mm flue liner.
□ Run the 2x flexible flues down
through the Ø230mm flue liner and
attach it to the Flue Spigot Plate as per
section C of this manual
□ Open the flue liner rodent guard
and close around the flexi flue. Rivet,
screw or cable tie the open end to
prevent it from opening. Bend the two
perpendicular tabs down and screw into
the flue liner using a short self tapping
screw. Note: Take care when installing the rodent guard to not cause damage to the flexi flue.
□ Install flue termination as per section C of this manual
Note: Ensure a power supply is within 1m of the rear of the appliance.
Rigid flue
Duravent 4x6"
Rigid Direct-vent
flue
Flue Liner
Coaxial to Colinear
Rodent Guard
conversion box
Ø265 mm
Ceiling hole
Ceiling Ring
225mm
Flue liner
2x Flexible
flue inner
AF700
Fireplace
Flexible flue clamped
to Flue Spigot Plate
FS730 Freestanding
Unit
630346_0 FS730 Builders and Architects Sheet

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FS730 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Escea FS730

  • Page 1 Flue Liner Gas Input/Consumption 22-25 MJ/hr Coaxial to Colinear Gas Connection lower right, 1/2” BSP female thread Rodent Guard securing holes to fix the FS730 to the conversion box Gas Type Natural Gas / ULPG (NZ) / Propane (Aus) floor. Weight...
  • Page 2 Do not place items or furnishings ontop of the freestanding fireplace, and ensure soft furnishings do not come in contact with the freestanding fireplace. 315mm 175mm 50mm 50mm 50mm IMPORTANT : Refer to the installation manual for mandatory clearances from the terminal. 630346_0 FS730 Builders and Architects Sheet...

Table of Contents