Borri B9000FXS 60kVA Product Manual

Borri B9000FXS 60kVA Product Manual

3ph/3ph
Table of Contents

Advertisement

PRODUCT MANUAL

UNINTERRUPTIBLE POWER SUPPLIES

 B9000FXS 60kVA (3PH / 3PH)
B9000FXS 80kVA (3PH / 3PH)
B9000FXS 100kVA (3PH / 3PH)
B9000FXS 125kVA (3PH / 3PH)
B9000FXS 160kVA (3PH / 3PH)
The present manual is an integrant part of the products technical back-up documentation. Read the warnings
with attention as they give important instructions concerning safety.
This equipment must be used only for its appointed operation. Any other use is to be considered incorrect and
therefore dangerous. The manufacturer cannot be held responsible for damages caused by incorrect, wrong and
unreasonable use.
Borri holds itself responsible only for the equipment in its original configuration.
Any intervention altering the structure or the operating cycle of the equipment has to be carried out and
authorized directly by Borri.
Borri cannot be held responsible of the consequences deriving from the use of non original spare parts.
Borri reserves its right to carry out technical modifications on the present manual and equipment without giving
any notice. If any typing errors or mistakes are detected, they will be corrected in the new versions of the
manual.
Borri holds itself responsible for the information given in the original version of the manual in Italian language.
Right of ownership – copying prohibited. Borri protects its rights on the drawings and catalogues by law.
Descrizione
Rev.
Description
F
Code upgrade
Borri S.p.A.
Via 8 Marzo, 2 – Soci
52010 Bibbiena (AR)
Tel. +39 0575 5351 – Fax +39 0575 561438
Web site: www.borri.it – e-mail: info@borri.it
Data
Date
20.05.13
E. Biancucci
Emesso
Approvato
Issued
Approved
F. Berti
English
Lingua
Pagina
di Pag.
Language
Page
of Pag.
E
1
54
Codice / Code
OMD10078

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B9000FXS 60kVA and is the answer not in the manual?

Questions and answers

Vipin mathews
August 8, 2025

Shall I get answer today.question is borri 160 kva ups need direct neutral for their operations.suppose for battery discharge ,if we open the 4 pole external input isolator it may affect or fail charger or booster board .so how can I manipulate battery discharge test manually.is it by opening RCB input ups breaker.can u advise me as early

Vipin mathews
August 8, 2025

For 160 kva ,can we check battery discharge test by switch off the rectifier input breaker of the ups .Is it any issue for that operations

This manual is also suitable for:

B9000fxs 125kvaB9000fxs 100kvaB9000fxs 160kvaB9000fxs 80kva

Table of Contents

Save PDF