5) Loosen t he Print head Screw and allow t he Print head t o fall free.
6) Rem ove t he Print head Cable.
I n st a lla t ion :
1) Carefully connect t he Print head Cable t o t he new Print head.
2) Posit ion t he Print head in t he Print head Carrier and t ight en t he Print head Screw.
3) Ensure t he Sensor properly seat ed and rot at e t he Print head Shield upward unt il it snaps int o
place.
4) Rot at e t he Print head Carrier upward unt il it snaps int o place.
Ch a pt e r 5 – M a in t e n a n ce a n d Adj u st m e n t s
312
Print head Shield
Print head Screw
Print head
Print head Cable
Sensor
5 9