Par. No.
Name
p29120[0..
Speed loop gain
.1] **
Description: Speed loop gain.
Two speed loop gains in total are available. You can switch between these two gains by configuring the digital
input signal G-CHANGE or setting relevant condition parameters.
The first speed loop gain is the default setting.
Dependency: The parameter value will be set to default after configuring a new motor ID (p29000).
p29121[0..
Speed loop integral time
.1] *
Description: Speed loop integral time.
Two speed loop integral time values in total are available. You can switch between these two time values by
configuring the digital input signal G-CHANGE or setting relevant condition parameters.
The first speed loop integral time is the default setting.
Dependency: The parameter value will be set to default after configuring a new motor ID (p29000).
p29130
Gain switching: Mode
selection
Description: Selects gain switching mode.
0: Disabled
1: Switch through DI-G-CHANG
2: Position deviation as switch condition
3: Pulse input frequency as switch condition
4: Actual speed as switch condition
Note: Only when the auto tuning function (p20021=0) is disabled can the gain switching function be used.
p29131
Gain switching condition:
Pulse deviation
Description: Triggers position deviation threshold for gain switching. If the gain switching function is enabled
and this condition is selected:
Switch from the first group of control parameters to the second group when the position deviation is larger
than the threshold.
Switch from the second group of control parameters to the first group when the position deviation is small-
er than the threshold.
p29132
Gain switching condition:
Position setpoint frequen-
cy
Description: Triggers pulse input frequency (PTI) threshold or internal position speed (IPos) threshold for gain
switching. If the gain switching function is enabled and this condition is selected:
1. PTI
Switch from the first group of control parameters to the second group when the pulse train input pulse
is higher than the threshold.
Switch from the second group of control parameters to the first group when the pulse train input is low-
er than the threshold.
2. IPos
Switch from the first group of control parameters to the second group when the speed of fixed position
setpoint is larger than the threshold.
Switch from the second group of control parameters to the first group when the IPos is smaller than the
threshold.
98
Min
Max
0.00
999999.00
0.00
100000.00
0
4
0
214748364
7
0
214700006
4
Factory
Unit
Data
Setting
type
[0]
Nms
Float
Motor
/rad
de-
pendent
[1] 0.30
[0] 15
ms
Float
[1] 20
0
-
I16
100
LU
I32
100
100
Float
0
LU/
min
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T
IM
T
IM
T
Getting Started
A5E36037886-003, 04/2017