Siemens SINAMICS V90 Getting Started page 96

Pulse train, uss/modbus interface
Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Par. No.
Name
p29035
VIBSUP activation
Description: Select the VIBSUP on/off.
Position setpoint filter can be activated (p29035) for IPos control mode.
0: Disable
Filter is not activated.
1: Enable
Filter is activated.
p29041[0..
Torque scaling
.1]
Description:
[0]: The scaling for the analog torque setpoint.
With this parameter, you can specify the torque setpoint corresponding to full analog input (10 V).
[1]: The scaling for the analog torque limit.
With this parameter, you can specify the torque limit corresponding to full analog input (10 V).
You can select the internal parameters or the analog input as the source of the torque limit with the combi-
nation of the digital input signals TLIM1 and TLIM2.
Index:
[0]: Torque set scale
[1]: Torque limit scale
p29042
Offset adjustment for
analog input 2
Description: Offset adjustment for the analog input 2.
p29043
Fixed torque setpoint
Description: Fixed torque setpoint.
You can select the internal parameters or the analog input as the source of the torque setpoint by configuring
the digital input signal TSET.
p29045
PTI: activate travel to
fixed stop
Description: Activate/deactivate "travel to fixed stop" function under PTI control mode.
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
p29050[0..
Torque limit upper
.2]
Description: Positive torque limit.
Three internal torque limits in total are available.
You can select the internal parameters or the analog input as the source of the torque limit with the combina-
tion of the digital input signals TLIM1 and TLIM2.
p29051[0..
Torque limit lower
.2]
Description: Negative torque limit.
Three internal torque limits in total are available.
You can select the internal parameters or the analog input as the source of the torque limit with the combina-
tion of the digital input signals TLIM1 and TLIM2.
p29060 *
Speed scaling
Description: The scaling for the analog speed setpoint.
With this parameter, you can specify the speed setpoint corresponding to full analog input (10 V).
96
Min
Max
0
1
0
[0] 100
[1] 300
-0.5000
0.5000
-100
100
0
1
-150
300
-300
150
6
210000
Factory
Unit
Data
Setting
type
0
-
I16
[0] 100
%
Float
[1] 300
0.0000
V
Float
0
%
Float
0
-
I16
300
%
Float
-300
%
Float
3000
rpm
Float
Effective
Can be
changed
IM
T
IM
T
IM
T
IM
U, T
IM
T
IM
T
IM
T
IM
T
Getting Started
A5E36037886-003, 04/2017