PREPARING THE WALL-MOUNTED EVAPORATOR (FAN COIL) UNIT
Required Tools:
•
Drill
•
5/32" Drill Bit
•
¼" Socket Drill Bit
•
¼" Wrench
•
Phillips-Head Screwdriver
•
Tape Measure
1. Remove the knockouts for the drain line, line set, and
electrical on the bottom or rear of the unit, depending
on your installation preference.
2. Remove the knockout on the bottom of the unit for
the bottle probe connector.
3. Remove the insulation from the knockout holes.
4. Remove the nut from the bottle probe connector.
5. Insert the bottle probe connector through the
knockout.
6. Secure the bottle probe connector to the housing
with the nut removed in step 4.
7. For ease of installation, remove the nine (9) screws
securing the top and remove the top.
•
Brazing Torch
•
Drywall Saw
•
Ladder
•
Level
•
Pliers
•
Pencil
Drain Pan
Circular Connection Mounting Location
Circular Connection
(Bottle Probe Input)
Unit Panel
www.whisperkool.com | Page 11
Platinum Split
Power
3/8" Suction
1/4" Liquid
Drain
Rubber Washer
Nut