For optimal results, allow the filter media to soak for a
minimum of 12 hours prior to install. This helps to main-
tain the manufacturer's specified filtration properties.
1. Complete all plumbing connections; inlet, outlet and drain
line.
2. Place bypass valve in bypass position. Turn on main
water supply and open a cold filtered faucet to flush piping
of any air and/or foreign material. Run until water is clear.
3. Open inlet valve slowly on bypass until it is in fully open
service position. Let water run to drain until clear. Plug
unit into 120V outlet and remove cover and plug trans-
former connection into 4-prong connection on circuit board
labeled power. Valve will return to service position once
this connection is made.
4. Let media soak for 15 minutes before proceeding.
pH — The pH level of the influent water must be 7.0 or higher
for iron oxidation reaction to proceed per the engineering

specifications.*

Iron — This system is rated for 6.0 ppm of ferrous (clear water)
and/or ferric (red water) iron.*
Hydrogen Sulfide — Sometimes referred to as "rotten egg" odor.
This system is rated for 5.0 ppm hydrogen sulfide. Hydrogen
sulfide levels vary depending on barometric pressure.*
Manganese — Limit 1.0 ppm; amounts present over 1.0 ppm may
gradually prevent iron removal. Note: For optimum manganese
reduction, pH should be greater than 8.5.*
Organic Matter (Tannins) – The presence of organic matter such
as tannins will prevent the oxidation process of converting the
dissolved element, such as iron or manganese, to a nonsoluble
precipitate or solid substance. In other words, organics can tie
up the iron preventing filtration. The presence of organics such
as tannins above 0.5 ppm voids any claims for this system
to perform as stated above. In some applications, tannin
levels below 0.5 ppm or the presence of other organics may
hinder the operation of this system.*
Specifications
Iron Storm Models
Iron Storm-10
Iron Storm-12
Iron Storm-13
(1) Water temps above 60° F will require a higher backwash rate. Consult factory.
Backwash Frequency
Iron Applications
0.3 - 2.0 ppm Iron - Every 3rd Day
2.0 - 4.0 ppm Iron - Every Other Day
4.0 - 6.0 ppm Iron - Every Day
5
Start Up Instructions
5. Initiate backwash by holding "REGEN" button down until
6. Let backwash continue until cycle is done. When "RINSE"
7. Repeat the backwash and settle steps (5&6) for a total of
NOTE: It takes several backwash cycles before all the media
fines are removed. Elimination of the 12 hour soak procedure
may result in more backwash cycles required to remove the
media fines.

Operating Conditions

Total Dissolved Solids (TDS) — While TDS does not directly
affect iron removal, it is a good indicator of potential interference.
Most waters have TDS less than 500 and generally present no
problems to iron reduction. If any ion becomes excessive, it may
cause failure of iron removal. A TDS more than 500 ppm voids
any claims for this system to perform as stated above.*
*For application parameters outside the specified operation
conditions or additional information regarding the listed
items, contact your dealer.
Do not install on chlorinated water supplies - harmful by-
products may be formed with ozone.
This unit is not intended to aid in the mitigation of microor-
ganisms and is not duly registered as a pesticidal device.
The Storm ozone filter must not be used on bacteriologi-
cally unsafe water supplies, such as those with with
positive Coliform or E Coli bacteria tests.
Small amounts of hardness (0.5-2 gpg) may occur initially
when filters installed on soft water.
Ozone Recharge Frequency
Hydrogen Sulfide Applications
0.1 - 1.0 ppm Hydrogen Sulfide - 100 Gallon
1.0 - 5.0 ppm Hydrogen Sulfide - 50 Gallon
piston movement is heard.
is displayed, push the REGEN button again to move into
the SERVICE position. Let the system settle for 5 minutes.
three times.
Failure to follow proper start-up may result in
equipment malfunction not covered by warranty.
Filter
Tank
Media
Inlet/
Outlet
Size
Cu. Ft
10"x54"
1.0
1"
12"x52"
1.6
1"
13"x54"
1.9
1"
Max.
(1)
Service
Backwash
Flow
Rate
GPM
GPM
4
5.3
6
7.5
7
10

Hide quick links: