Installation Instructions & Start-Up - Hellenbrand 7,156,995 Owner's Manual

Promate-6 / iron curtain-2.0
Table of Contents

Advertisement

Installation Instructions
Your new Iron Curtain™ model IC‑2.0 allows for simple instal-
lation and start up. Installation diagrams are provided to assist
you. Use of these diagrams and the following procedures
will ensure that the system is properly installed.
1. Follow all state and local plumbing and electrical
codes!
2. The inlet check valve must be installed in the upflow posi-
tion on the raw water supply feeding the aeration tank.
(See figure 1 page 7 for proper check valve installation
procedures)
3. When installing an Iron Curtain Filter system it is common
to provide filtered water to some fixtures such as the
kitchen cold faucet. This is typically done as a matter
of personal preference. In rare occassions it has been
noted that the customer may experience some air in
the filtered water line on the morning after regeneration.
It has proven to be beneficial to plumb the line for the
filtered‑only water fixture in a downward direction before
the inlet to the softener (12 inches recommended), then
make a reverse turn and go upward toward the fixture.
Understanding that air always rises to the highest point
in a water system, and it cannot naturally flow downward.
(Figure 1, page 7)
4. The raw water supply from the outlet of the check valve
must be connected to the down‑flow inlet connection on
Demand Aeration Iron Curtain 2.0 Start-up Instructions
for start-up instructions with chemical feed, see pages 25 and 26
Do not oPen Filter ByPaSS Until inStrUCteD to Do So!
Wire aeration cable to ProMate6 control, (black wire to RLY
1 and red wire to V+, install jumper wire between RLY 1 &
RLY 2). Plug power connection to PC board and plug unit
into 120V outlet, unit will cycle to service mode.
Must install bypass on each tank
Do not backwash in first 24 hours
Complete all plumbing connections; inlet, outlet, drain line
and connect 3/8" line at back of aeration assembly and run
to drain (ok to connect to filter drain line).
1.
Verify both tanks are bypassed.
2.
Flush cold water piping to nearest faucet until air
gone and water is clear.
3.
Slowly open inlet valve on aeration tank
only to fully open position, slowly open aeration
tank outlet.
Leave filter in bypass.
4.
5
read cOMPleTelY PrIOr TO STarTInG SYSTeM
the aeration tank. refer to the stickers marked inlet/
outlet for proper connections. A factory by‑pass valve
is available and should be installed on the aeration tank
assembly. Leave the aeration tank on by‑pass at this
time.
5. The outlet from the aeration tank is then connected to the
inlet of the filter tank. A factory by‑pass valve is available
and should be installed on the filter tank assembly.
6. Connect the outlet of the filter system to the water system
lines you are filtering.
7. The IC‑2.0 aeration head assembly has a 3/8" drain con-
nection that must be run to a drain. This can tee into the
drain line of the filter or to a drain independent of the filter
drain. Drain line emits surges of excess air from aeration
tank and must be secured. Tubing has been supplied.
8. There is a 1/4" tube size vent port off of the solenoid valve
which is vented to the atmosphere. This will normally
expel very little moisture unless an internal seal fails within
the valve body. This vent should be run to a drain to
prevent any water damage to the surrounding area,
should the solenoid fail. This must drain downward
to an open atmospheric drain separate from the filter
drain.
9. Recommend 1" diameter pipe between aeration tank
and filter tank.
5.
Push & hold REGEN button; this will initiate
an air recharge cycle, filter automatically advances
to Backwash when air recharge complete, push
REGEN button to advance to Rinse position.
6.
Slowly open filter inlet, unplug power from board.
Rinse until clear and close inlet to filter; wait
7.
until water stops running to drain.
8.
Plug power back into PC board, unit will cycle to
service.
9.
Open filter inlet and outlet.
10.
Push SET CLOCK button and use UP/DOWN
arrows to set time of day.
For application specific gallon setting, see page 6 of manual.
Failure to follow proper start-up may result in
equipment malfunction not covered by warranty.