PROMATE 6 IC STORM WITH AIR REGEN SPECIFICATIONS
MODEL
FACTORY PRESET MINUTES
Backwash # 1 : Seconds
Draw DN # 1 : Minutes
*Water Usage (Gallons) sequence # 1
BACKWASH # 2 : MINUTES
RINSE # 2 : MINUTES
DRAW DN # 2 : MINUTES
*Water Usage (Gallons) sequence # 2
Maximum Service Flow Rate
Media, Cubic Feet
Mineral Tank Dimension
Drain Line Flow Control- GPM
Injector
Max. Iron Concentration
Max. Hydrogen Sulfide Concentration
Max. Manganese Concentration
* Based upon 50 psi water pressure
** Do not use Storm filter on chlorinated water supplies.
***For levels higher than the maxium concentrations listed, contact manufacturer. Local water conditions may
require different application parameters.
Note: Manual regeneration follow sequence # 2
This unit is not intended to aid in the mitigation of microorganisms and is not duly registered as a pesti-
cidal device.
The Storm ozone filter must not be used on bacteriologically unsafe water supplies, such as those with
with positive Coliform or E Coli bacteria tests.
15
PROMATE 6.0 IC STORM w/AIR REGEN SPECIFICATIONS
PM6 IC Storm 10
PM6 IC Storm 12
0:10
8
6.5
12
6
8
100
4.0
1
10x54
5.3
Dk. Green
Dk. Green
6.0
5.0
1.0
PM6 IC Storm 13
0:10
12
9.8
12
6
12
142
6.0
1.6
12x52
13x54
7.5
Dk. Green
6.0
5.0
1.0
Revised 8/12/2015
0:10
12
10.2
12
6
12
187
7.0
1.9
10
6.0
5.0
1.0
800591