Necessary Deviation Adjustment Item For Each Signaling And Mode - Kenwood NX-5400 Service Manual

700/800mhz digital transceiver
Hide thumbs Also See for NX-5400:
Table of Contents

Advertisement

4.9.1 Necessary Deviation adjustment item for each signaling and mode

The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following
example. In the case of the signaling "QT (Analog Wide 5k)", this signaling is composed of three elements [Balance, Maximum Devi-
ation (Analog Wide 5k) and QT Deviation (Analog Wide 5k)]. Please adjust Balance and Maximum Deviation (Analog Wide 5k) before
adjusting QT Deviation (Analog Wide 5k).
Mode Signaling
Analog Audio
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
QT
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. QT Deviation
[Analog Wide 5k]
DQT
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. DQT Deviation
[Analog Wide 5k]
LTR
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. LTR Deviation
[Analog Wide 5k]
DTMF
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. DTMF Deviation
[Analog Wide 5k]
MSK
1. Balance adjust
(Fleet
2. Maximum Deviation
sync)
[Analog Wide 5k]
3. MSK Deviation
[Analog Wide 5k]
P25
NXDN Audio
CWID
• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 6) has already adjusted, please skip
Step1 and adjust from Step2.
• Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) is common with all the analog signaling deviations and CWID Deviation
(NXDN Very Narrow). If Balance and Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) (Transmitter Section 7) have already
adjusted, please skip Step2 and adjust from Step3.
1-58 (No.RA016<Rev.001>)
Wide 5k
Wide 4k
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. QT Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. DQT Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. LTR Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. DTMF Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. MSK Deviation
[Analog Wide 4k]
-
-
-
Necessary adjustment and order
Narrow
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. QT Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. DQT Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. LTR Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. DTMF Deviation adjust
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. MSK Deviation
[Analog Narrow]
-
1. Balance
2. P25 High Deviation
3. P25 High Deviation
(H-CPM)
-
1. Balance adjust
2. Maximum Deviation
[NXDN Narrow]
-
Very Narrow
-
-
-
-
-
-
-
1. Balance adjust
2. Maximum Deviation
[NXDN Very Narrow]
-
1. Balance adjust
2. Maximum Deviation
[NXDN Very Narrow]
3. CWID Deviation
[NXDN Very Narrow]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-5400 f2Nx-5400 k2Nx-5400 k3Nx-5400 f3