■ Mode, Signaling, Necessary adjustment and order

Mode
Signaling
Analog
Audio
1. Balance adjust
2. Analog Deviation adjust [Wide]
QT
1. Balance adjust
2. Analog Deviation adjust [Wide]
3. QT Deviation adjust [Wide]
DQT
1. Balance adjust
2. Analog Deviation adjust [Wide]
3. DQT Deviation adjust [Wide]
LTR
1. Balance adjust
2. Analog Deviation adjust [Wide]
3. LTR Deviation adjust [Wide]
DTMF
1. Balance adjust
2. Analog Deviation adjust [Wide]
3. DTMF Deviation adjust [Wide]
2TONE
1. Balance adjust
2. Analog Deviation adjust [Wide]
3. TONE Deviation adjust [Wide]
MSK
1. Balance adjust
(FleetSync)
2. Analog Deviation adjust [Wide]
3. MSK Deviation adjust [Wide]
NXDN

Receiver Section

Item
Panel tuning mode
1. AF level
[Panel test mode]
setting
1) CH-Sig : 1-1
SSG output:
-47dBm (1mV)
(MOD: 1kHz,
Dev: ±1.5kHz)
2. Sensitivity 1
1) Adj item:[SENS1]
adjust
Adjust:[***]
(BPF adjust)
2) Adj item:
[L SENS1]→
[L' SENS1]→
[C SENS1]→
[H' SENS1]→
[H SENS1]
Adjust:[***]
Press [ ] key to store
the adjustment value.
ADJUSTMENT
Necessary adjustment and order
Wide
1. Balance adjust
2. Analog Deviation adjust [Narrow]
1. Balance adjust
2. Analog Deviation adjust [Narrow]
3. QT Deviation adjust [Narrow]
1. Balance adjust
2. Analog Deviation adjust [Narrow]
3. DQT Deviation adjust [Narrow]
1. Balance adjust
2. Analog Deviation adjust [Narrow]
3. LTR Deviation adjust [Narrow]
1. Balance adjust
2. Analog Deviation adjust [Narrow]
3. DTMF Deviation adjust [Narrow]
1. Balance adjust
2. Analog Deviation adjust [Narrow]
3. TONE Deviation adjust [Narrow]
1. Balance adjust
2. Analog Deviation adjust [Narrow]
3. MSK Deviation adjust [Narrow]
1. Balance adjust
-
2. NXDN Deviation adjust [Narrow]
Condition
PC test mode
equipment
1) Test Channel
SSG
Channel : 1
DVM
Test Signaling
AF VTVM
Mode : Analog
Dummy
Signaling : 1
load (4Ω)
SSG output:
-47dBm (1mV)
(MOD: 1kHz,
Dev: ± 1.5kHz)
1) Adj item:[Sensitivity 1]
2) Adj item:[Low]
[Low']
[Center]
[High']
[High]
Press [Apply All] button to
store the adjustment value.
Narrow
Measurement
Test-
Unit
Terminal
Unit
ANT
Ext.SP
connector
NX-800
Very Narrow
-
-
-
-
-
-
-
1. Balance adjust
2. Analog Deviation adjust [Narrow]
3. CWID Deviation adjust [Very Narrow]
Adjustment
Specifications/
Parts
Method
[
],[ ]
Volume Up/Down
2.83V± 0.3V
knob to obtain
2.83V AF output.
(2.0W @ 4Ω load)
[Panel
Write the value as
Output voltage
tuning
followings
adjustment of
mode]
IC206
[
],[ ]
[L SENS1] / [Low]
: 90
[PC test
[L' SENS1] / [Low']
mode]
: 119
[ ],[ ]
[C SENS1] / [Center]
: 150
[H' SENS1] / [High']
: 184
[H SENS1] / [High]
: 224
Remarks
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents