4.6.1 Necessary Deviation adjustment item for each signaling and mode

The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following
example. In the case of the signaling "QT (Analog Wide)", this signaling is composed of three elements [Balance, Maximum Deviation
(Analog Wide) and QT Deviation (Analog Wide)]. Please adjust Balance and Maximum Deviation (Analog Wide) before adjusting QT
Deviation (Analog Wide).
Mode
Signaling
Analog
Audio
QT
DQT
2TONE
DTMF
MSK
DMR
Audio
• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 4) has already adjusted, please skip
Step1 and adjust from Step2.
• Maximum Deviation (Analog Wide/Analog Narrow) is common with all the analog signaling deviations.
If Balance and Maximum Deviation (Analog Wide/Analog Narrow) (Transmitter Section 6) have already adjusted, please skip Step2
and adjust from Step3.
Wide
1. Balance
2. Maximum Deviation
[Analog Wide]
1. Balance
2. Maximum Deviation
[Analog Wide]
3. QT Deviation [Analog Wide]
1. Balance
2. Maximum Deviation
[Analog Wide]
3. DQT Deviation [Analog Wide]
1. Balance
2. Maximum Deviation
[Analog Wide]
3. Single Tone Deviation
[Analog Wide]
1. Balance
2. Maximum Deviation
[Analog Wide]
3. DTMF Deviation
[Analog Wide]
1. Balance
2. Maximum Deviation
[Analog Wide]
3. MSK Deviation
[Analog Wide]
-
Necessary adjustment and order
1. Balance
2. Maximum Deviation
[Analog Narrow]
1. Balance
2. Maximum Deviation
[Analog Narrow]
3. QT Deviation [Analog Narrow]
1. Balance
2. Maximum Deviation
[Analog Narrow]
3. DQT Deviation [Analog Narrow]
1. Balance
2. Maximum Deviation
[Analog Narrow]
3. Single Tone Deviation
[Analog Narrow]
1. Balance
2. Maximum Deviation
[Analog Narrow]
3. DTMF Deviation
[Analog Narrow]
1. Balance
2. Maximum Deviation
[Analog Narrow]
3. MSK Deviation
[Analog Narrow]
1. Balance
2. Maximum Deviation [DMR]
Narrow
(No.RA035<Rev.001>)1-29