NOTE:
When using the O2 controller, 6 Minutes of pellets must be weighted and
inserted in screw capacity.
O2% MIN POWER
Temperature
The amount of excess oxygen in the smoke at low performance.
Magazine
Sets the amount of fuel so that the excess oxygen is at the required amount.
If the pellet burner smokes at low performance, set a higher percentage of oxygen.
Auto combustion
If the photo sensor has problems recognizing the ignition, this could be caused by
the ignition being too weak; set a higher value to increase the feed.
Man. combustion
The flame should be yellowish.
Timer
O2% MAX POWER
The amount of excess oxygen in the smoke at full performance.
Cleaning / power
Sets the amount pellets so that the excess oxygen is at the required amount.
O2 Control
If the pellet burner smokes at full performance, set a higher percentage of oxygen.
If the flame is angry and sputtering, set a lower percentage of oxygen.
OFF / DISPLAY / ON
Turns oxygen regulation on/off.
Oxygen regulation set to ON –
The burner sets the amount of pellets to suit the required percentage of oxygen.
Oxygen regulation set to DISPLAY –
You can read the percentage, but the burner does not set the amount of pellets.
The tighter the boiler, the more you get from oxygen regulation.
It is recommended to fit the chimney with a draught stabilizer,
this will reduce the draught and cut the amount of air flowing back into the boiler.

TECH SETUP

PELLETS
Ignition
Setting the amount of pellets for ignition.
Pause
NOTE: can only be adjusted if auto combustion is on NO.
PERIOD
O2
Setting maximum ignition duration.
POWER
Fine tune
Setting performance of electrical ignition.
PID regulation
FIRE LIMIT
Setting amount of light required to interrupt ignition.
Temp. alarm
BLOWER IGNIGTION
Setting the blower speed at ignition.
Accessories
TOTAL STARTS
The total number of time the ignition has been used.
TOTAL HOUR
The total hours the ignition has been used.
Ignition
MAX MINUTES
Maximum pause time, 245 = pause always, 0= off
Pause
burner will then ignite electrically automatic after stop.
O2
BLOWER PAUSE
Blower speed during pause.
Fine tune
PAUSE DIFFERENCE TEMP.
The setting defining how far the boiler temperature is dropping below the desired
PID regulation
value before the burner restarts.
Temp. alarm
EXTINGUISH TIME
Stopping / cleaning blower time
Accessories
Very important that time is long enough to burn the last remaining pellets
in the burner head, to prevent over heating,
Manual
NBE pellet system
USER GUIDE
(Press the SET button for 8 seconds.)