ACTUAL CONTENT
Temperature
Adjusting the content of the magazine.
Magazine
RESET CONSUMPT.
Putting the pellets kg counter to zero.
Auto combustion
Man. combustion
Timer
Cleaning / power
O2 Control
SCREW CAPACITY
Temperature
After setting the auger performance in 360 seconds the control will
Magazine
automatically calculate the amount of pellets in low power and high power,
pellets in pause , and pellets for ignition
Auto combustion
Under normal conditions these numbers will be correct.
To increase combustion, set the value DOWN.
Man. combustion
To reduce combustion, set the value UP.
Timer
CHIMNEY DRAUGHT
With a strong chimney draught the ventilator performance will be higher,
Cleaning / power
At low steam and during pause.
If the amount of chimney draught is increased,
O2 Control
the automatic calculation sets more pellets in low steam and during pause.
The smaller the chimney draught and the greater the back pressure of the boiler,
the lower the value must be.
The greater the chimney draught and the lower the back pressure of the boiler,
the higher the value must be
YES/NO
Switching automatic calculations on/off.
If automatic calculation is on, only the auger performance can be set.
PELLETS LOW
Temperature
Setting the amount of pellets for low performance.
Magazine
Should be set so there is a flame when running 10% power.
NOTE: can only be adjusted if auto combustion is on NO
Auto combustion
PELLETS HIGH
Setting the amount of pellets for full performance.
Man. combustion
Should be set so that combustion is powerful when running at 100% power.
Timer
NOTE: can only be adjusted if auto combustion is on NO
PAUSE PELLETS
Cleaning / power
Setting the amount of pellets for during lag.
O2 Control
If in doubts about the settings, use the automatic calculation program.
NOTE: can only be adjusted if auto combustion is on NO
STARTS / MINUTE
Setting how many time auger is running / minute.
Manual
NBE pellet system
USER GUIDE