Boiler Temp; Difference Temp; Hot Water Temp; Dif. Hotwater - Opop H 418 Manual

Wood pellets burner
Hide thumbs Also See for H 418:
Table of Contents

Advertisement

There can be 3 run mode to see in the display
You change by pressing up / down
RUN MODE 1:
Boiler temp./ Smoke temp. / Hot water temp.
Return temp./ Tank content / Light sensor / Kwh / Clock mode.
Circulation Pump / 3 way valve. / Ignition.
When making ignition, you can see time counting down.
RUN MODE 2:
Boiler temp. / Return temp. / Smoke temp. / O2 %.
Flow system. / Kwh / light sensor. / Burner temp.
Circulation Pump / Ignition
When making ignition, you can see time counting down.
RUN MODE 3:
Watt pr m2. / Outside temp. / Tank content /Total hour /
Total use of pellets. / Time
Press SET and the display will show SETUP for standard settings.
The UP button is used to increase the setting and for force-running the auger ( hold for longer than 5 seconds ).
To force run the auger for an long time , hold UP button while switching power to control box
The DOWN button is used to decrease the setting and switch the controls on/off ( hold for 10 seconds ).
Resets alarms.
.

BOILER TEMP.

Temperature
Setting the required boiler temperature.
Magazine
The burner sets the performance higher or lower depending on the figure entered
( set point ).
Auto combustion

DIFFERENCE TEMP.

Man. combustion
The setting defining how far the boiler temperature, can go over set point before
pause or stop.
Timer

HOT WATER TEMP.

Setting the required hot water temperature.
Cleaning / power
Only to be adjusted if hot water temp. sensor and 3 way valve is fitted.
O2 Control
and activated in accessories in the Tech Setup. ( 3 way valve on L5 or L6 )

DIF. HOTWATER

The setting defining how far the temperature can drop, before starting making hot
water again.
PUMP STOP TEMP.
The setting defining what temperature the pump stops,
pump will always run, when the pellets burner is burning.
Must be activated in accessories in the Tech Setup ( pump on L5 or L6 )
SUMMER STOP .
The setting defining what outside temperature the burner stops, .
An outside temperature sensor must be fitted in T5
SUN STOP .
The setting defining how power full the sun must be before the burner stops, .
An W/m2 sensor must be fitted in T6
CALIBRETING SUN STOP .
The sensor calibrating it self to 1000w/m2
If it is out of range it can be done manual.
Manual
NBE pellet system
USER GUIDE