CLOCK
Temperature
Setting the clock.
Magazine
PERIOD HEATING
Setting the running time, when clock is starting the burner.
Auto combustion
1.START HEATING
Starts the burner at this time , running time will be "period heating"
Man. combustion
2.START HEATING
Timer
Starts the burner at this time , running time will be "period heating"
3.START HEATING
Cleaning / power
Starts the burner at this time , running time will be "period heating"
4.START HEATING
O2 Control
Starts the burner at this time , running time will be "period heating"
PERIOD H. WATTER
Setting the running time, when clock is starting making hot water.
1.START H. WATER
Starts the burner at this time , running time will be "period heating"
2.START H. WATER
Starts the burner at this time , running time will be "period heating"
3.START H. WATER
Starts the burner at this time , running time will be "period heating"

CLEANING INTERVAL

Temperature
Sets how often the burner should be cleaned.
Magazine
If you often heat on low load, the interval can be reduced to 5 minutes,
with 5 seconds of cleaning.
Auto combustion

CLEANING TIME

Man. combustion
Set the cleaning time.
The shorter the intervals the shorter the time should be.
Timer
BLOWER CLEANING
Setting the power of blower when the burner cleaning.
Cleaning / power

MINIMUM POWER

O2 Control
Setting minimum performance.
If the pellet burner always works on low load and is having some difficulties,
the minimum performance can be increased so the burner occasionally turns off.

MAXIMUM POWER

Setting maximum performance.
If the pellet burner rapidly reaches a high temperature,
the maximum performance should be reduced.
COMPRESSOR CLEANING
Adjusting after how many kg of pellets, the burner make an compressor cleaning
Compressor cleaning must be fitted and activated in accessories in the Tech setup
( magnet air valve on L5 or L6 )
COMPRESSOR WAIT
Adjusting how long time before activating compressor cleaning,
the burner stop feeding pellets to the combustion.
COMPRESSOR TIME
Adjusting how long time the air valve is open when cleaning.
COMPRESSOR BLOWER
Adjusting the blower speed when cleaning with compressor.
Manual
NBE pellet system
USER GUIDE
HH:MM
HH:MM
HH:MM
HH:MM
HH:MM
HH:MM
HH:MM
HH:MM
HH:MM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H 430H 440H 460Comfort

Table of Contents