R3016 12U/6X Manuals - Simrad R3016 12U/6X Installation Manual

Radar system
Hide thumbs Also See for R3016 12U/6X:
Table of Contents

Advertisement

POWER
8
The R3000 Power supply unit
System nominal input is 24 VDC. The power supply unit converts the available 24 VDC power
source up to the transceiver's operating voltage. The transceiver input voltage is higher to
minimize the effect of voltage drop due to cable length.
Output power cables are available in 15, 30 and 65 m lengths.
The Heater kit
The optional Heater kit is used when installing the heater in the transceiver. The heater
warms up the radar transceiver to ensure safe start-up and operation. The main components
of the Heater kit are:
the R3000 Power supply unit - provides the additional output required to drive heater
element
the Heater upgrade kit - all the parts that are to be included in the transceiver unit
the cable - connects the R3000 Power supply unit to the transceiver heater power
connector
Power cables for connection between R3000 Power supply unit and Heater kit are available
in 15, 30 and 65 m lengths.
SI80 Signal Interface unit
The optional SI80 Signal Interface unit is used to provide an additional IEC 61162-2 port.
Connection to the R3016 Control unit is made via NMEA 2000. The SI80 provides power and
termination for the backbone.

R3016 12U/6X manuals

The following documentation is delivered with the R3016 12U/6X Radar system:
R3016 12U/6X Operator manual (988-10911-00n)
User descriptions of the radar and of the features included in the system.
Intended audience: System operator.
R2009/R3016 Quick Guide (988-10951-00n)
Graphical document describing the keys and the main functions.
Intended audience: System operator.
R3016 12U/6X Installation and System wiring manual (988-10912-00n)
Mechanical installation and wiring, technical specifications and mechanical drawings for all
system components.
Intended audience: Shipyard installation personnel.
R3016 12U/6X Configuration and maintenance manual (988-10913-00n)
System setup/configuration, commissioning, trouble shooting, maintenance procedures,
replacement procedures for replaceable parts and spare parts listing.
Intended audience: Installation and service engineers.
R3016 Control unit Mounting template (988-10917-00n)
1:1 cut-out template with dimensions.
Ú Note:
The last digit in the part numbers is the document's revision code. The latest
version of all documents can be downloaded from the product website on
www.navico.com/commercial.