Power Supply Diagnostics; Control Unit Power And Alarm Output Connection - Simrad R3016 12U/6X Installation Manual

Radar system
Hide thumbs Also See for R3016 12U/6X:
Table of Contents

Advertisement

1
Transceiver power cable (15 m in the example)
2
Ethernet cable
3
Heater power cable (15 m in the example)
4
Transceiver
5
R3000 power supply
6
Fused supply (30 A fuse for each supply with normal action, able to cut 32 VDC)
7
Ship's 24 VDC supply
The longer 30 m and 65 m cables have additional cores which require connection to the
extra screw terminals, per the diagram below.
PWR OUT
1
1
Wired with 15 m cable
2
Wired with 30 m cable
3
Wired with 65 m cable

Power supply diagnostics

There are two LEDs on the front cover of the R3000 power supply unit. They provide basic
diagnostic information on the connections: wiring and power supply connection status.
The following table covers the various possible sequences.
LED
Color
STATUS
Green
POWER
Green
OFF
Red
Red
Ú Note:
The power supply has an initialization sequence at startup, and will momentarily
illuminate the red LED, this is normal behavior.

Control unit power and alarm output connection

The R3016 Control unit power cable has four wires, two of which provide power to the unit,
and two for the alarm output.
Wiring
| R3016 12U/6X Installation manual
PWR OUT
PWR OUT
2
3
Pattern
On constant
On constant
N/A
On constant
Blinking
Meaning
Output voltage (52 VDC) is
available to the transceiver
Input supply is good, voltage is
within acceptable range
No supply, or protection fuse is
blown
R3000 switch set to OFF
Output overload
Input voltage too high (>45 V
DC)
Input voltage too low (<17 V DC)
Output voltage too high (>60V)
Temperature too high (>125° C)
Output overload