Appendix D - ADM Error Codes
Error
Code
Error Name
Error Description
The voltage to the MCM has
Motor Control
V1H1
dropped to a level where
Undervoltage
performance is greatly affected
Red Blanket
V4A6
Overvoltage
Blue Blanket
V4B5
Overvoltage
Red Inline
V4A3
Overvoltage
Blue Inline
V4B1
Overvoltage
High line voltage
Red Hose
V4A2
Overvoltage
Blue Hose
V4B4
Overvoltage
Red Chiller
V4A7
Overvoltage
Blue Chiller
V4B8
Overvoltage
The voltage to the MCM has
Motor Control
reached an unsafe level and
V4H0
Overvoltage
has been shutdown in an
attempt to prevent damage
USB Update
The ADM tried to upload a
W0U0
Failed
system settings file but failed
Motor
An error has been detected on
WBH1
Encoder Fault
the motor position sensor
M1 Material
The material rod failed to move
WDF1
Rod Shift Fail
on a straight head
The motor has reached a
speed that should not be
High Motor
WKH1
reached in normal operation
Speed
and was shutdown to prevent
possible damage
98
Error
Type
Cause
Tripped circuit breaker
Alarm
Supply lines providing
low voltage
Incoming line voltage is
Alarm
too high
Supply lines providing
Alarm
high voltage
System Settings file is
corrupt
Alarm
System Settings file is
intended for another
system
Failing sensors
Alarm
Loose connection
Stuck material rod
Alarm
No power to directional
valve
No power to directional
valve
Bad directional valve
connection
Directional valve failure
Hydraulic power pack
failure
Alarm
Defective encoder
Motor no longer coupled
to hydraulic pump
Supply tube from
hydraulic pump to
manifold is loose or
broken
Broken motor shaft
Solution
Visually check circuit breaker for a tripped condition
Check incoming voltage to ensure it is above the
minimum operating voltage
Measure voltage across disconnect switch. Voltage
should measure between 190 and 264 Vac.
Check incoming voltage to ensure it is below the
maximum operating voltage
Replace the system settings file with a backup or new
file
Ensure that the first line in the settings.txt file contains
the text GMS
. If not replace the file with the proper
system update file.
If error persists the motor will need to be replaced
Ensure the d-sub connector to the motor is connected
and the wiring is intact
Check that material rod is able to freely move
Make sure the directional valve has power
Make sure the directional valve has power
Make sure the cord to the directional valve is
connected to the correct port and the cord is not
damaged
The directional valve will need to be replaced
The hydraulic power pack will need repair
Replace encoder
Reset coupler per specifications and retighten set
screws
Retighten or replace supply tube
Replace motor