Maintenance Chart - Clarke SE Ranges Operating & Maintenance Instructions

Table of Contents

Advertisement

SYMPTOM
Condensation at outlet Piping installation incorrect.
points.
Electric Motor too hot:
maximum temperature Faults in electrical installation
90 C (194 F).
Machine running but
not pumping air into
receiver (10 HP and
above).

MAINTENANCE CHART

CHECK LIST
DAILY
Oil Level
Check
Air receiver
Drain
Intake filter
Oil breather
Fan and Cooling
Fins
Inlet and Outlet
valves
Non-return valve
Belt tension
Big end bearings
Main bearings
Piston rings
OTHER PRODUCTS WITHIN OUR RANGEIn addition to Air Compressors from 3–80 cfm, we
offer a vast range of airtools and airline equipment. Please ask your local dealer for
details ofour range or a copy of our Power Products Catalogue
PROBABLE CAUSES
Compressor taking in air
which is too warm.
Delivery temperature of air
from air receiver too high.
Operational voltage too low.
or electric motor.
Cooling fins of electric motor
blocked by dirt.
Air exhausting from solenoid
after starter has changed from
star to delta.
WEEKLY
6 MONTHLY
Change
Check/Clean
Check/Clean
Clean
Check
Clean
Replace if worn
Check/Adjust
Check
Replace if worn
Check
Check
17
REMEDY
Consult your local dealer.
Obtain better fresh-air
supply for compressor.
a) Use a larger air receiver.
b) Insert an aftercooler.
Call an electrician.
Call an electrician.
Clean cooling fins.
Check solenoid valve.
Call an electrician to
check starter.
Replace if necessary
Replace if worn
Does not apply to
direct drive
Replace if worn
Replace if worn

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ve ranges

Table of Contents