Temperature
Range
Display
Resolution
Temperature
Accuracy*
Temperature
Coeffi cient
Real Time
Clock Tolerance
Max
Differential
Common Mode
Voltage
Temperature
Scale
Standards
* Accuracy is specified for ambient temperatures between 64°F and
82°F (18°C and 28°C) for a period of 1 year. The above specifications
do not include thermocouple error.
Test Equipment Depot - 800.517.8431 -
99 Washington Street Melrose, MA 02176
10

ELECTRICAL SPECIFICATIONS

J-type
-346°F~2192°F
K-Type
-328°F~2498°F
T-type
-328°F~752°F
E-Type
-238°F~1832°F
0.1°F<1000°F
J-type
1°F≥1000°F
0.1°F<1000°F
K-Type
1°F≥1000°F
0.1°F<752°F
T-type
N/A
0.1°F<750°F
E-Type
1°F≥750°F
±[0.1% + 1.4˚F(0.8˚C)]
J, K, E
Type
<-148˚F(-100˚C) add 0.2% of reading
±[0.3% + 2.7˚F(1.5˚C)]
T Type
<-148˚F(- 100˚C) add 0.5% of reading
0.01% of reading 0.1°F per °F(+0.05°C per °C) for
<+64°F (+18°C) or +82°F (+28°C)
[Below -148°F (-100°C): add 0.05% of reading for J,
K, and E-type; and 0.1% of reading for T-type]
About 1 second per day
1V Maximum voltage difference
(between any pair of inputs)
ITS-90 (International Temperature Scale of 1990)
N.I.S.T. Monograph 175 revised to ITS-90
TestEquipmentDepot.com
-210°C~1200°C
64K ~ 1472K
-200°C~1370°C
74K ~ 1642K
-200°C~400°C
74K ~ 673K
-150°C~1000°C
124K ~ 1273K
0.1°C<550°C
0.1K<824K
1°C≥550°C
1K≥824K
0.1°C<750°C
0.1K<1000K
1°C≥750°C
1K≥1000K
0.1°C<400°C
0.1K<673K
N/A
N/A
0.1°C<400°C
0.1K<673K
1°C≥400°C
1K≥673K