Interruption of the descaling cycle

Cleaning and maintenance

Weekly cleaning of the brew group

1
2
4219_460_3729_1_booklet_A5_v1.indd 16
Once the descaling cycle has started, you must complete it till
the very end without turning off the machine. In case you get
stuck during the cycle or in case of power failure or accidental
disconnection of the power cord, you can exit by pressing the
standby button. If this occurs, empty and rinse carefully the water
tank, then fill it up to the CALC CLEAN level. Follow the instructions
in chapter 'First installation', section 'Manual rinsing cycle' before
brewing any beverage. If the cycle was not completed, the machine
will require another descaling cycle to be performed at your earliest
convenience.
Clean the brew group once per week.
1
Remove the coffee grounds container and open the service
door.
2
Remove the coffee residues drawer.
3
To remove the brew group, press the lever and pull the brew
group out of the machine.
4
Rinse the brew group with fresh water and let it air dry.
5
To place the brew group back, make sure that the lever is in
contact with the base of the brewing unit.
Note: If it is not in contact with the base, push it down.