ioLogik E1200 Series
Quick Installation Guide
Fourth Edition, April 2015
Overview
The ioLogik E1200 series comes with 2 embedded Ethernet switch
ports that can form a daisy-chain topology, which is the easiest way
to add more Ethernet devices to a network or connect your ioLogiks
in series. Moxa's free Active OPC Server offers active (or "push")
communication that works between Moxa's ioLogik units and
HMI/SCADA systems, providing instant I/O status reports by "Active
Tags." The event-driven active tags result in an I/O response time
that is faster than other OPC Server packages.
Model Selection:
ioLogik
DI
DO
DIO
Relay
AI
AO
RTD
E1210
16
-
-
-
-
-
-
E1211
-
16
-
-
-
-
-
E1212
8
-
8
-
-
-
-
E1213*
8
4
4
-
-
-
-
E1214
6
-
-
6
-
-
-
E1240
-
-
-
-
8
-
-
E1241
-
-
-
-
-
4
-
E1242
4
-
4
-
4
-
-
E1260
-
-
-
-
-
-
6
E1262
-
-
-
-
-
-
-
*The ioLogik E1213 has source DOs.
Package Checklist
1 ioLogik E1200 series remote I/O product
Documentation and software CD
Quick installation guide (printed)
Specifications
System
Ethernet:
2 x 10/100 Mbps switch ports, RJ45
Protection:
1.5 KV magnetic isolation
Protocols:
Modbus/TCP, TCP/IP, UDP, DHCP, Bootp,
HTTP
Power Input:
24 VDC nominal, 12 to 36 VDC
Wiring:
I/O cable max. 14 AWG
Dimensions:
27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
Weight:
under 200 g
Operating
Standard Models: -10 to 60°C (14 to
Temperature:
140°F)
Operating
Wide Temperature Models: -40 to 75°C
Temperature:
(-40 to 167°F)
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Ambient Relative
5 to 95% (non-condensing)
Humidity:
P/N: 1802012001013
– 1 –
Altitude:
Up to 2000 m
Note: Contact Moxa if you require products guaranteed to function
properly at higher altitudes.
Standards and
UL 508, CE, FCC Class A
Certifications:
Warranty Period:
5 years (excluding ioLogik E1214*)
Details:
See www.moxa.com/warranty
*Because of the limited lifetime of power relay, products that use
this component are covered by a 2-year warranty.
Digital Input
Sensor Type:
NPN, PNP, and Dry contact
I/O Mode:
DI or Event Counter
Dry Contact:
• On: short to GND
• Off: open
Wet Contact
• On: 10 to 30 VDC
(DI to COM):
• Off: 0 to 3 VDC
Isolation:
3K VDC or 2K Vrms
Counter/Frequency:
250 Hz, power off storage
Digital Output (Sink)
I/O Mode:
DO or Pulse Output
TC
Pulse Wave
1 ms/500 Hz
-
Width/Frequency:
-
Over-voltage
45 VDC
-
Protection:
-
Over-current
2.6 A (4 channels @650 mA)
-
Protection:
-
Over-temperature
175°C (typical), 150°C (min.)
-
Shutdown:
-
Current Rating:
200 mA per channel
-
Isolation:
3K VDC or 2K Vrms
8
Digital Output (Source)
I/O Mode:
DO or Pulse Output
I/O Type:
Source
Current:
0.5A per channel
Voltage:
For DIO channel:
15 to 30 VDC (ext power voltage)
For DO channel:
15 to 30 VDC (ext power voltage), 12 or 9
VDC configurable by jumper.
Pulse Wave
1 ms/500 Hz
Width/Frequency:
Over-voltage
41 VDC
Protection:
Over-current Limit:
6 A
Over-temperature
175°C (typical), 150°C (min.)
Shutdown:
Output Current Rating: 1.5 A per channel
Relay Output
Type:
Form A (N.O.) relay outputs, 5A
Contact Rating:
5 A @ 30 VDC, 5 A @ 250 VAC, 5 A @ 110
VAC
Inductance Load:
2 A
Resistance Load:
5 A
Breakdown Voltage:
500 VAC
Relay On/Off Time:
1500 ms (max.)
Initial Insulation
1G min. @ 500 VDC
Resistance:
– 2 –
Expected Life:
100,000 times (typical)
Initial Contact
30 milli-ohms (max.)
Resistance:
Pulse Output:
0.3 Hz at rated load
Analog Input
Type:
Differential input
Resolution:
16 bits
I/O Mode:
Voltage / Current
Input Range:
0 to 10 VDC, 4 to 20 mA
Accuracy:
± 0.1% FSR @ 25°C
± 0.3% FSR @ -10 and 60°C
± 0.5% FSR @ -40 and 75°C
Sampling Rate (all
12 samples/sec
channels):
Input Impedance:
10M ohms (min.)
Built-in Resistor for
120 ohms
Current Input:
Analog Output
Resolution:
12 bits
Output Range:
0 to 10 VDC, 4 to 20 mA
Voltage Output:
10 mA (max.)
Accuracy:
± 0.1% FSR @ 25°C
± 0.3% FSR @ -40 and 75°C
Load Resistor:
Internal register: 400 ohms
Note: 24 V of external power is required when loading > 1000 ohms.
RTD
Input Type:
PT50, PT100, PT200, PT500, PT1000
Resistance:
1–310, 1–620, 1–1250, 1–2200 ohms
Sampling Rate:
12 samples/sec (all channels)
Resolution:
16 bits
Accuracy:
± 0.1% FSR @ 25°C
± 0.3% FSR @ -40 and 75°C
Input Impedance:
625k ohms
Thermocouple Input
Sensor Type:
J, K, T, E, R, S, B, N
Millivolt Type:
± 78.126 mV, ± 39.062 mV, ± 19.532 mV
Fault and Overvoltage
± 35 VDC (power off); +30 VDC, -25 VDC
protection:
(power on)
Sampling Rate:
12 samples/sec (all channels)
Resolution:
16 bits
Accuracy:
± 0.1% FSR @ 25°C
± 0.3% FSR @ -40 and 75°C
Input Impedance:
10M ohms
Installation
Connecting the Power
Connect the +12 to +36 VDC power line to the ioLogik E1200's
terminal block V+ terminal; connect the ground from the power
supply to the V- terminal. Connect the ground pin (
) if earth
ground is available.
– 3 –
NOTE For safety reasons, wires connecting the power supply
should be at least 2 mm in diameter (e.g., 12 gauge wires).
Jumper Settings
Models with DIO, AI, or external power channels require configuring
the jumpers inside the enclosure. Remove the screw located on the
back panel and open the cover to configure the jumpers.
DIO mode configurations are
Analog mode configurations are
shown above
shown above
(Default: DO Mode).
(Default: Voltage Mode).
DOs on the ioLogik E1213 have 3
possible external (EXT) power
configurations, which are shown
to the right. Only one field power
can be selected at a time (JP10 /
12V JP5 / 9V JP11) and the
jumper must be inserted
vertically, not horizontally
(Default: Field Power JP10).
NOTE The ioLogik E1213 has 4 pure DO channels and 4 hybrid DIO
channels. For the 4 pure DO channels, you can use the
jumpers to select the power configuration output (i.e., field
power, 12 V, 9 V). But for the 4 hybrid DIO channels, you
cannot use the jumpers to select the power configuration
output. Instead, you can only use the jumpers to set the DIO
channels to either DI mode or DO mode.
Mounting
There are two sliders on the back of the unit for DIN rail and wall
mounting.
1. Mounting on a DIN rail: Pull out the bottom slider, latch the
unit onto the DIN-rail, and push the slider back in.
2. Mounting on the wall: Pull out both the top and bottom sliders
and align the screws accordingly.
- 4 -

Advertisement

loading

Summary of Contents for Moxa Technologies ioLogik E1210

  • Page 1 Altitude: Up to 2000 m Expected Life: 100,000 times (typical) Note: Contact Moxa if you require products guaranteed to function Initial Contact 30 milli-ohms (max.) properly at higher altitudes. Resistance: ioLogik E1200 Series Standards and UL 508, CE, FCC Class A Pulse Output: 0.3 Hz at rated load Certifications:...