10.1.6

Input / Output Status

To enter input / output status:
Press and hold the MENU button, then press the UP button for 4 seconds. This enters the Diagnostic
mode.
Press the UP button three times. The current input /output status will be displayed.
• If a device is on or a door is open, the respective LCD will be on.
• Return to normal operation by pressing the MENU button.
• NOTE: Only the first 6 LCD's are used. The last 5 are not used.
Compressor on.
Defrost heater on.
Example.
The Compressor is on.
The FC fan is on.
The PC fan is on.
NOTE: In I/O mode the illumination of the LCD will turn off if either PC doors are opened.
10.1.7

Fault History

The Fault History will indicate the last fault that occurred with the product. However, this will only be
displayed for a periods of 4 days, after which it can only be accessed through a download. It will also
indicate if there are any further faults with the display board. If an icemaker display fault has occurred, these
will be indicated by fault codes F40 or F41 on the LCD Display.
NOTE: This is fault history and may not necessarily be a current fault.
10.1.8

To Manually Force A Defrost

While pressing and holding the MENU button, press the DOWN button for 4 seconds.
NOTE: The defrost cycle will not start if the defrost sensor is above +8
The defrost cycle follows a predefined sequence. Refer to Section 4.3 for details of the defrost cycle.
10.1.9

LCD Display

When the PC door is opened, the backlight of the display will turn off and the functions will not operate i.e.:
the water dispenser will not work and temperature setting etc. cannot be altered.
However, if the door is left open for 5 minutes, the interior light will turn off and the alarm will sound. At this
point the display will start working and all functions will be operative.
Input/Output Status
FC fan on when door
is closed.
Upper door open.
Lower drawer open
PC Fan on.
Low Ambient heater on.
Light on.
O
C.