Defrost Cycle; R134A System - Fisher & Paykel 635 Active Smart Service Manual

Table of Contents

Advertisement

321144
4.3

Defrost Cycle

4.3.1

R134a System

The following table outlines the defrost cycle of an R134a refrigerant system Active Smart
COMPRESSOR
TURNS OFF
2 MINUTES
NORMAL RUN
WARM UP
DEFROST ELEMENT
TURNS ON
DEFROST TIME:
TARGET IS 18 MINUTES OR
SENSOR REACHES 8
MAXIMUM IS 40 MINUTES
DEFROST
If 40 minutes has elapsed, defrost
would be aborted if defrost sensor
O
has not reached 8
defrosts are aborted, Fault Code 2
is displayed.
®
refrigerator.
DEFROST ELEMENT
TURNS OFF
O
C.
4 MINUTES
DRIP TIME
O
C (46
F). If 2
Diagram 4.3.1
22
COMPRESSOR
BOTH PC AND FC
TURNS ON
FANS TURN ON
30 SECONDS
DELAY
BACK TO NORMAL RUN