Compressor Faults; Compressor Runs Continuously - Fisher & Paykel 635 Active Smart Service Manual

Table of Contents

Advertisement

321144

16.10 Compressor Faults

Compressor runs
continuously
Refer to Section

16.11 Compressor Runs Continuously

Refer to Section
16.3
Compressor will
not run and is cold
Refer to Section
16.11
Are the LEDs
on the
display
module
illuminated?
Yes
Is
refrigeration
taking place?
Yes
Are the FC/PC
reaching set
No
temperatures?
No
Check for loss of
gas (leak) or
blockage
Compressor will
not run and is hot
to touch
Refer to Section
16.13
With FC door
closed and PC
No
door open, press
Mode button
Check for loss of
gas (leak) or
No
blockage
Check for correct fitting of
sensors. Check sensor
Yes
resistances (refer Section
140
to touch
16.12
4.22)