  • Page 1 ONSIP OPTZ33D5W...
  • Page 2 ’ ’ Warnings & Cautions If you fail to read this information and handle the product incorrectly, faulty or malfunction as well as death or serious injury may occur. This unit should be installed by trained personnel. Immediately stop using when the product emits smoke or abnormal heat.
  • Page 3 ’ ’ Graphic Indicators: Warning: Death or Serious Injury will occur without following Warning. Caution : Operational Problem(Faulty & Malfunction) will occur without complying with Caution Reference : Technical Information for Users Rev.1.2 Aug. 2012 3 of 31...
  • Page 4: Table Of Contents

    ’ ’ Table of Contents Table of Contents ....................4 1 Introduction ....................5 1.1. Overview of OPTZ33D5W ....................5 1.2. Features of OPTZ33D5W ....................5 1.3. Specification of OPTZ33D5W ..................7 2 Product Description ..................8 2.1. Package Contents ......................8 2.2.
  • Page 5: Introduction

    ’ 1 Introduction OPTZ33D5W, as a state-of-the-art Speed Dome Network Camera based on integrated Embedded Software technologies such as H.264 & MJPEG, G.726 & PCM Video & Audio Compression, Embedded Web Server, Embedded Streaming Server, various Network Protocols, transmits synchronized video and audio data in real...
  • Page 6 ’ ’ Detailed Features of Speed Dome Camera (Analog Camera Module, PTZ)  12X Zoom Mini Speed Dome Hot Keys This camera supports various 12X Optical Zoom with 16X digital zoom functions for ease of control by other controllers or DVRs. ±0.02°...
  • Page 7: Specification Of Optz33D5W

    CMS Software 3rd Party CMS Contact to Speco Dynamic IP DDNS support Supported by Speco’s Management Server User ID & Password Protection, IP Filtering, Audio per user Security Management and Bi-directional audio communication configuration control Sync to PC Sync to PC Time...
  • Page 8: Product Description

    1. Wall Mount Bracket 2. CD (Manual, Software) 2. Adaptor 3. Screw (Ø 4x16 : 5EA) 4. Terminal Block (5PIN : 2EA) Note: Standard DC Adaptor can be purchased from Speco. ONSIP-Installer OPTZ33D5W Speco-NVR PC based Client for H.264 Speed Dome...
  • Page 9: Physical Description

    ③ DIP Switch ④ Terminal Block ⑤ Main Body Detailed Terminal Block View of OPTZ33D5W - Network Connection 10/100 Base T: As Ethernet Port, connects OPTZ33D5W to LAN with 10Mbps or 100Mbps via RJ-45. Rev.1.2 Aug. 2012 9 of 31...
  • Page 10 Audio Input) Connect 12 Volt DC adaptor to this terminal for supplying power to the network camera. Power adapter which is compliant to the specification for OPTZ33D5W should be used. Misuse of power supply can cause damage to OPTZ33D5W. DC12V SPECO assumes no responsibility for misuse of the power supply.
  • Page 11: Detailed Specification Of Analog Camera Module & Ptz

    ’ ’ 2.3.2. Dimension of OPTZ33D5W Dimension of OPTZ33D5W & & Class 12X A/F Camera Module 360˚ PAN Rotation Angle Manual Max 150˚/Sec(64 Steps) Rotation Max. 250˚ /Sec Preset Speed -2˚ ~ 90˚ PAN/TILT TILT Rotation Angle Manual Max.150˚/Sec(64 Steps) TILT Speed Max.250˚...
  • Page 12 ’ ’ 1 Relay Output Aux Output Auto Flip ON / OFF OSD Menu English, Italian, Polish Communication RS-485 Power Consumption Max. 10W Power Power Standard DC12V, 3.35A 1/4" Super HAD CCD Image Sensor NTSC 811(H) * 508(V) 410K No. of Pixels 795(H) * 596(V) 470K No.
  • Page 13: Bracket Installation

    ’ ’ 3 Bracket Installation A. Installation Preparation A-1: Ceiling Mount Type. 1. Fix the surface mount adaptor with 4 pcs of screws on the desired place(FIG.4). 2. When use Pipe, please note the standard size of Pipe.(FIG.5) A-2: Set the DIP Switches as in the following picture. Rev.1.2 Aug.
  • Page 14 ’ ’ If required to control Speed Dome Camera via System Controller, Please set the RS-485 Communication Configuration as below. Baud Rate = 2400 bps Data = 8 bit Stop Bit = 1 Parity = No Flow Control = No A-3: Wall Mount Type 1.
  • Page 15 ’ ’ Fix the edge of Cable Gland on the bottom case and coat the attached line between top & bottom of Cable Gland bottom case with silicon. 2. Drill 4 holes on the wall to fix bracket as Fig. A-4. 3.
  • Page 16 ’ ’ A-4: Corner Mounting A-5: Pole Mounting Rev.1.2 Aug. 2012 16 of 31...
  • Page 17: Installation

    ’ ’ 4 Installation Recommended Specification of PC for Camera Configuration & Monitoring will be as below. Class Recommended Specification Remark Pentium-4 3Ghz Graphic Card Higher than ATI Chip-Set based 64M 1600x1200(UXGA) LAN Card Higher than 100Mbps Windows XP Web Browser Higher than Internet Explorer 6.0 * OS: Windows 2000 Professional / XP / Vista / 7 Rev.1.2 Aug.
  • Page 18: Quick Installation Guide

    IEEE802.3at PoE Product LAN Cable Connection Diagram Connect PC and ONSIP OPTZ33D5W to Network Device (HUB or Switch) Prepare a PC which needs to be connected to Network. Connect PC (or Lab-Top) with Product as Fig 4-1. Power will be applied to product separately via Power Device (AC Adaptor).
  • Page 19: Install Speco-Nvr

    ’ ’ Speco-NVR is a multi-channel CMS program for to IP camera or Video server. Install Speco-NVR on remote PC to connect to these products. It is needed to assign connection information to Speco-NVR program before connection. Insert the CD provided with product into the PC and install the Speco-NVR.
  • Page 20 ’ ’ Click on the field in ③ for sorting and rearranging the list. Select network mode that best suits from the drop down list in ⑤. You can choose either Static or ADSL and Auto (DHCP), respectively. If ADSL and Auto are selected, the fields in ⑥ is deactivated.
  • Page 21: Remote Connection To Ip Camera

    For the use of Web Viewer, Active-X module should be installed. If internet access is available, you can download it by accessing Camera or if you install Speco-NVR, Active-X module will be installed together. Connection to Admin Page Basic Control...
  • Page 22: Connection Through Speco-Nvr

    User ID, Password and port and then click the save button. After assignment procedure, you must click the SAVE button. You can see the live video when you click the live view button as below. When you exit Speco-NVR, you have to input the ID/PW, admin/1234. Camera Assignment...
  • Page 23 ’ ’ All Parameters of ONSIP OPTZ33D5W are initially set as factory default. So you must change them with appropriate value to your network configuration by accessing via Admin Tool. Admin Tool Access Method is as below. http://[IP Address]:[HTTP Port No.]/ admin.htm Admin Tool Access ID / Password: admin/1234.
  • Page 24: Trouble Shooting

    ’ ’ 5 Trouble Shooting  Network Connection Status Check (Ping Test) You can check the Network Connection Status by doing Ping Test. - Start > Run > cmd > Ping IP Address (EX>ping 172.16.42.51). - If you get the response such as “Reply from~”, Network Configuration & Connection Status is good. Please re-try to access or refer to other trouble shooting category.
  • Page 25: Windows Vista And Windows 7 User For Record & Capture Problem

    & & For the use of Video Recording & Capture function on Speco-NVR and Web Viewer, Windows Vista and Windows 7 Users are required to configure “User Account Configuration” and “Program Execution Entitlement Configuration”. If not configure, Recorded File won’t be generated or Captured Image on Web Viewer won’t be saved.
  • Page 26 ’ ’ Windows 7 Configuration 1. User Account Configuration 1) Select “User Account” on Control Panel 2) Select “Change User Account Control Setting” 3) Set the Alarm Level at the lowest “Never Notify” Rev.1.2 Aug. 2012 26 of 31...
  • Page 27 ’ ’ 2. Program Execution Entitlement Configuration 1) Select “NVR” icon on the wallpaper 2) Select “Properties” menu popped up by clicking right button on Mouse 3) Select Check Box of “Run this program as an administrator” from the compatibility Tap. Rev.1.2 Aug.
  • Page 28: Technical Support

    ’ ’ Please contact Speco Technical Support if you have any problems troubleshooting the device. For the quickest solution, please have all information below readily available; 1. Product Model Name 2. Serial No. & Mac Address 3. Date of Purchase 4.
  • Page 29: Appendix

    “ ” Connect the two wires of the sensors. The sensor type can be set by Virtual System Controller of Speco-NVR. 1) Please run Speco-NVR ,click on the “System Controller” 2) Select the “menu” button on Virtual System Controller, then OSD menus are displayed.
  • Page 30: Aux" Port For Relay Output

    Electrical Signal Switching of AC/DC 30V, 1A, Relay Junction Point will be closed by Alarm Output. Connect the as relay desired device to AUX (AUX1,AUX2) port of OPTZ33D5W regardless of electrical polarity. AUX1, AUX2 is refer to Out+ ,Out– respectively in the diagram below.
  • Page 31: Connection Of Sensor And Relay Output Device

    ’ ’ 6.1.3.1. Sensor Connection Diagram Photo Coupler NO/NCType Open CollectorType Sensor1+ Sensor Sensor Device Device Sensor1- +12V Sensor Sensor Power Power Supply Supply Sensor Connection Diagram 6.1.3.2. Relay Output Device Connection Diagram Alarm Relay Switch Power Supply 1V~30VDC/AC,1A Device Power Supply(30V Optional...