Torque Requirements; Hydraulic Oil - JLG 600A Operation And Safety Manual

Table of Contents

Advertisement

Torque Requirements

Table 6-13. Torque Requirements
Description
Bearing To Chassis
Bearing To Turntable
Wire Rope
Wheel Lugs
Engine Mounting Bolts
Engine Manifold Mounting Bolts
*Check swing bearing bolts for security after first 50 hours of operation and
every 600 hours thereafter. (See Swing Bearing in Section 3.)
3121204
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
Interval
Torque Value (Dry)
Hours
See Note
50/600*
See Note
50/600*
15 ft. lbs (20 Nm)
150
See Section 6.4
150
165 ft. lbs. (231 Nm)
A/R
30 ft. lbs. (42 Nm)
A/R
– JLG Lift –

Hydraulic Oil

Table 6-14. Hydraulic Oil Specifications
HYDRAULIC SYSTEM
OPERATING TEMPERATURE
RANGE
+0° to +180° F (-18° C to +83° C)
+0° F to +210° F (-18° C to +99° C)
+50° F to +210° F (+10° C to +210° C)
NOTE: Hydraulic oils must have anti-wear qualities at least to API
Service Classification GL-3, and sufficient chemical stabil-
ity for mobile hydraulic system service. JLG Industries
recommends Mobilfluid 424 hydraulic oil, which has an
SAE viscosity index of 152.
NOTE: When temperatures remain below 20° F (-7° C), JLG
Industries recommends the use of Mobil DTE 13M.
SAE VISCOSITY
GRADE
10W
10W-20, 10W-30
20W-20
6-9