Installation

BE SURE TO REINSTALL THE FILTER MAGNET INTO THE HOUSING
BEFORE INSTALLING NEW SEAL
1. Install the mounting plate to lock off O-ring seal.
2. If equipped, install the retaining bolt seal.
3. Install the housing seal.
4. Drop the magnet into the bottom of the filter housing.
5. Install the filter into the housing.
6. If equipped, install the retaining bolt into the filter hous-
ing.
7. Install the filter up to the bottom of the electric lock off.
8. Tighten the filter bowl retainer to 106 in lbs (12 Nm).
9. Open manual shut-off valve. Start the vehicle and leak
check the propane fuel system at each serviced fitting.
Refer to Propane Fuel System Leak Test.
3121204
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6.8
THE PROPANE FUEL SYSTEM OPERATES AT PRESSURES UP TO 312
PSI (21.5 BAR). TO MINIMIZE THE RISK OF FIRE AND PERSONAL
INJURY, RELIEVE THE PROPANE FUEL SYSTEM PRESSURE (WHERE
APPLICABLE) BEFORE SERVICING THE PROPANE FUEL SYSTEM COM-
PONENTS.
RESIDUAL VAPOR PRESSURE WILL BE PRESENT IN THE FUEL SYS-
TEM. ENSURE THE WORK AREA IS WELL VENTILATED BEFORE DIS-
CONNECTING ANY FUEL LINE.
– JLG Lift –

PROPANE FUEL SYSTEM PRESSURE RELIEF

To relieve propane fuel system pressure:
1. Close the manual shut-off valve on the propane fuel
tank.
2. Start and run the vehicle until the engine stalls.
3. Turn the ignition switch OFF.
6-41