Carrier 30RB060-390 Installation Instructions Manual page 5

Aquasnap air-cooled chillers and / with greenspeed technology
Hide thumbs Also See for 30RB060-390:
Table of Contents

Advertisement

SEE PREVIOUS PAGE
FOR REMAINDER
OF MODEL NUMBER
NOMENCLATURE
Refrigeration Circuit Options
- – No Suction Line Insulation
0 – Suction Insulation
1 – Suction Service Valves
2 – Low Ambient Head Pressure Control Operation
3 – Suction Insulation, Suction Service Valves
4 – Suction Insulation, Low Ambient Head Pressure Control Operation
5 – Suction Service Valves, Low Ambient Head Pressure Control Operation
6 – Suction Insulation, Service Valves, Low Ambient Head Pressure
Control Operation
7 – Minimum Load Control
8 – Suction Insulation, Minimum Load Control Operation
9 – Suction Service Valves, Minimum Load Control Operation
B – Low Ambient Operation, Minimum Load Control Operation
C – Suction Insulation, Suction Service Valves, Minimum Load
Control Operation
D – Suction Insulation, Low Ambient Head Pressure Control Operation,
Minimum Load Control Operation
F – Suction Service Valves, Low Ambient Head Pressure Control Operation,
Minimum Load Control Operation
G – Suction Insulation, Suction Service Valves, Low Ambient Head Pressure
Control, Operation, Minimum Load Control Operation
H – Suction Service Valves, High-Efficiency Variable Condenser Fans
J – Suction Insulation, Suction Service Valve, High-Efficiency Variable
Condenser Fans
K – High-Efficiency Variable Condenser Fans
L – Suction Insulation, High-Efficiency Variable Condenser Fans
M – Suction Service Valves, High-Efficiency Variable Condenser Fans,
Minimum Load Control Operation
N – Suction Insulation, Suction Service Valve, High-Efficiency Variable
Condenser Fans, Minimum Load Control Operation
P – High-Efficiency Variable Condenser Fans, Minimum Load Control Operation
Q – Suction Insulation, High-Efficiency Variable Condenser Fans,
Minimum Load Control Operation
LEGEND
CRN
Canadian Registration Number
EMM
Energy Management Module
GFI-CO
Ground Fault Interrupting Convenience Outlet
LON
Local Operating Network
SCCR
Short Circuit Current Rating
VFD
Variable Frequency Device
XL
Across-the-Line Start
*Refer to Table 1 on page 2 for modular unit combinations.
†Sponsored by ASHRAE (American Society of Heating, Refrigerating and Air-
Conditioning Engineers).
NOTE: A "Z" in position 11 indicates a special order machine. Digits following
do not correspond to tables.
Fig. 1 — AquaSnap
F
6
8
RB
190
®
Chiller Model Number Designation (cont)
Packaging/Security Options
L – No Packaging
0 – Skid
1 – Skid, Top Crate, Bag
3 – Coil Trim Panels
4 – Skid, Coil Trim Panels
5 – Skid, Top Crate, Bag, Coil Trim Panels
7 – Coil Trim Panels, Upper and Lower Grilles
8 – Skid, Coil Trim Panels, Upper and Lower Grilles
9 – Skid, Top Crate, Bag, Coil Trim Panels, Upper and Lower Grilles
C – Trim Panels, Upper and Lower Grilles, Upper Hail Guards
D – Skid, Trim Panels, Upper and Lower Grilles, Upper Hail Guards
F – Skid, Top Crate, Bag, Trim Panels, Upper and Lower Grilles,
Upper Hail Guards
H – Skid, Full End Covers
J – Skid, Top Crate, Bag, Full End Covers
K – Full End Covers
Controls/Communication Options
- – None
0 – EMM
1 – Remote Service Port, GFI-CO
2 – EMM, Remote Service Port, GFI-CO
3 – BACnet† Communication
4 – BACnet Communication, EMM
5 – BACnet Communication, Remote Service Port, GFI-CO
6 – BACnet Communication, EMM, Remote Service Port, GFI-CO
7 – BACnet Translator
8 – BACnet Translator, EMM
9 – BACnet Translator, Remote Service Port, GFI-CO
B – BACnet Translator, EMM, Remote Service Port, GFI-CO
H – LON Translator
J – LON Translator, EMM
K – LON Translator, Remote Service Port, GFI-CO
L – LON Translator, EMM, Remote Service Port, GFI-CO
Electrical/Low Sound Options
- – Single Point Power Connections, XL, Terminal Block
0 – Single Point Power Connections, XL, Terminal Block, High SCCR
3 – Dual Point Power Connections, XL, Terminal Block
4 – Dual Point Power Connections, XL, Terminal Block, High SCCR
7 – Single Point Power Connections, XL, Non-Fused Disconnect
8 – Single Point Power Connections, XL, Non-Fused Disconnect, High SCCR
C – Dual Point Power Connections, XL, Non-Fused Disconnect
D – Dual Point Power Connections, XL, Non-Fused Disconnect, High SCCR
G – Single Point Power Connections, XL, Terminal Block, Cmpr Blankets
H – Single Point Power Connections, XL, Terminal Block, Cmpr Blankets, High SCCR
J – Dual Point Power Connections, XL, Terminal Block, Cmpr Blankets
K – Dual Point Power Connections, XL, Terminal Block, Cmpr Blankets, High SCCR
L – Single Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets
M – Single Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets,
High SCCR
N – Dual Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets
P – Dual Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets,
High SCCR
Q – Single Point Power Connections, XL, Terminal Block, Cmpr Blankets,
Cmpr Enclosures
R – Single Point Power Connections, XL, Terminal Block, Cmpr Blankets,
Cmpr Enclosures, High SCCR
S – Dual Point Power Connections, XL, Terminal Block, Cmpr Blankets,
Cmpr Enclosures
T – Dual Point Power Connections, XL, Terminal Block, Cmpr Blankets,
Cmpr Enclosures, High SCCR
V – Single Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets,
Cmpr Enclosures
W – Single Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets,
Cmpr Enclosures, High SCCR
X – Dual Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets,
Cmpr Enclosures
W – Dual Point Power Connections, XL, Non-Fused Disconnect, Cmpr Blankets,
Cmpr Enclosures, High SCCR
5
a30-5704