Carrier 30RB060-390 Installation Instructions Manual page 4

Aquasnap air-cooled chillers and / with greenspeed technology
Hide thumbs Also See for 30RB060-390:
Table of Contents

Advertisement

30RB – Air-Cooled AquaSnap® Chiller
Design Series
Nominal Sizes
060 110
170
275
360*
070 120
190
300
390*
080 130
210
315*
090 150
225
330*
100 160
250
345*
Voltage
1 – 575-3-60
5 – 208/230-3-60
2 – 380-3-60
6 – 460-3-60
Condenser Coil Options
- – Aluminum Fin/Copper Tube
0 – Copper Fin/Copper Tube
1 – Aluminum Pre-Coat Fin/Copper Tube
2 – Aluminum E-Coat Fin/Copper Tube
3 – Copper E-Coat Fin/Copper Tube
4 – Microchannel (MCHX)
5 – E-Coat, Microchannel (MCHX)
Hydronics Option†
- – No Pump Installed
0 – Single Pump, 3 HP
1 – Single Pump, 5 HP
2 – Single Pump, 7.5 HP
3 – Single Pump, 10 HP
4 – Single Pump, 15 HP
6 – Dual Pump, 3 HP
7 – Dual Pump, 5 HP
8 – Dual Pump, 7.5 HP, Low Head
9 – Dual Pump, 7.5 HP, High Head
B – Dual Pump, 10 HP
C – Dual Pump, 15 HP
F – Single Pump, 3 HP with VFD
G – Single Pump, 5 HP with VFD
H – Single Pump, 7.5 HP with VFD
J – Single Pump, 10 HP with VFD
K – Single Pump, 15 HP with VFD
M – Dual Pump, 3 HP with VFD
N – Dual Pump, 5 HP with VFD
P – Dual Pump, 7.5 HP, Low Head with VFD
T – Dual Pump, 7.5 HP, High Head with VFD
Q – Dual Pump, 10 HP with VFD
R – Dual Pump, 15 HP with VFD
Z – Special order designation
LEGEND
CRN
Canadian Registration Number
EMM
Energy Management Module
GFI-CO
Ground Fault Interrupting Convenience Outlet
LON
Local Operating Network
SCCR
Short Circuit Current Rating
VFD
Variable Frequency Device
XL
Across-the-Line Start
*Refer to Table 1 on page 2 for modular unit combinations.
†Sponsored by ASHRAE (American Society of Heating, Refrigerating and Air-
Conditioning Engineers).
NOTE: A "Z" in position 11 indicates a special order machine. Digits following
do not correspond to tables.
318
190
RB
®
Fig. 1 — AquaSnap
Chiller Model Number Designation
SEE NEXT PAGE
FOR REMAINDER
OF MODEL NUMBER
NOMENCLATURE
Cooler Options
- – Integral Cooler, CRN (Canada)
0 – Integral Cooler, Cooler Heater, CRN (Canada)
4 – Integral Cooler, Microchannel (MCHX), CRN (Canada)
5 – Integral Cooler, Cooler Heater, Microchannel (MCHX), CRN (Canada)
G – Integral Cooler, no CRN
H – Integral Cooler, Cooler Heater, no CRN
K – Integral Cooler, Microchannel (MCHX), no CRN
L – Integral Cooler, Cooler Heater, Microchannel (MCHX), no CRN
R – Integral Cooler, Microchannel (MCHX), Heat Recovery, no CRN
S – Integral Cooler, Cooler Heater, Microchannel (MCHX), Heat Recovery,
no CRN
T – Integral Cooler, Microchannel (MCHX), Heat Recovery, CRN (Canada)
V – Integral Cooler, Cooler Heater, Microchannel (MCHX), Heat Recovery,
CRN (Canada)
4
a30-5694

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30rb080-390

Table of Contents