Specifications

Item
Model Name
Type
Ignition
Minimum Pressure for Maximum flow
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption
Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
38
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Hot Water Return
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
NG
LP
25°C Rise
58°C Rise
Specification
KM3211WH
Indoor or Outdoor, Wall Hanging
Power Vented
Direct Ignition
200 kPa
3.5 L/min.
61.5 cm(Height) x 46.4 cm(Width) x 24 cm(Depth)
29 kg
1.1 Litre
3/4"
3/4"
3/4"
240 VAC (50Hz)
NG:100W
NG:135W
LP:150W
LP:115W
Freeze Prevention 115W
Freeze Prevention 140W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR),
Electric Leakage Prevention Device, Overheat
Prevention Device, Freezing Prevention Device,
Fan Rotation Detector
Remote Controller, Anchoring Screws
Maximum Performance
250 MJ/h
250 MJ/h
32 L/min.
13 L/min.
3 - 32 L/min.
37 - 48, 50, 55, 60, 65, 70, 75, 80°C (Bridge 83°C)
40, 50, 60, 83°C
KM3211WHQ
32 kg
1/2"
Minimum Performance
20 MJ/h
18 MJ/h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km3211whq