Initial Setup Wizard; Region; Guidance Width - Raven Envizio Pro Installation & Operation Manual

Table of Contents

Advertisement

Chapter 5

Initial Setup Wizard

The initial setup wizard will automatically begin when the Envizio Pro or Envizio Pro II is powered up for the first
time. This wizard will step through the initial settings and calibration values required for operation of the field
computer and control system. This process should only take a few minutes to complete and is only required
during the initial power up sequence.
Any values or settings programmed during the initial setup wizard can be modified or refined later through the
Tools Menu.
Note:
Many of the values entered in the initial setup wizard are required for guidance and/or product
control features of the control system. Therefore, the more accurate these values can be
measured, the more accurate the control system will be.
The following sections may help complete the initial setup wizard. To confirm the settings displayed on a
screen and proceed with the initial setup wizard, touch the 'Next' or 'Accept' icons. If available, the 'Previous'
icon will step back to the previous Setup screen.
Previous

Region

The first screen displayed during the initial setup wizard is the Region screen. Select the preferred language
and units for display on the field computer.
Metric - centimeters, liters, hectares, kilometers per hour
English - inches, gallons, acres, miles per hour
Turf Units - inches, gallons per 1000 square feet, miles per hour
Select the desired units of pressure to be used with an optional Glide Series AutoBoom system.
kilo Pascals
pounds per square inch
Time Zone Settings
Touch the Time Zone icon in the upper right corner to view and modify time zone settings. The default
selections will allow the field computer to automatically configure the time zone and daylight savings for the
region of operation. To manually change the time zone, select the 'Manual Time Zone' option and enter the
UTC (Coordinated Universal Time) offset hours for the local time zone.

Guidance Width

The guidance width should be entered as the width of the boom, implement or header which actually
completes an operation while the vehicle drives a swath. For example, the measured guidance width for a
sprayer boom should not include fence row nozzles or foam markers and the guidance width of a combine
header should be the cutting surface, not the overall header width.
Use the on-screen keypad to enter the guidance width in inches (English) or centimeters (Metric) for the boom,
implement or header.
38
Next
Envizio Pro and Envizio Pro II Installation and Operation Manual
Accept

Advertisement

Table of Contents
loading

This manual is also suitable for:

Envizio pro ii