Installing Devices In Flange Design - Siemens Sitrans FX300 Operating Instructions Manual

Vortex flowmeters
Hide thumbs Also See for Sitrans FX300:
Table of Contents

Advertisement

SITRANS FX300

3.6.2 Installing devices in flange design

Figure 3-12: Installing devices in flange design
1 Gasket
2 Bolts with fixing nuts
• Use bolts and fastening nuts 2 to attach the measuring device to one side of the flange.
• While doing so, insert the gaskets 1 between measuring sensor and flange and align them.
• Check that the gasket is concentric and that it is not protruding into the pipe cross-section.
• Install the gasket, bolts and fastening nuts on the other side of the flange.
• Align the measuring device and the gaskets so they are concentric.
• Now tighten all nuts bit by bit alternately across the diagonal.
06/2009 - SFIDK.PS.050.F2.02 A5E02100423
www.siemens.com/flow
INSTALLATION
3