ELECTRICAL
Model
Voltage
Ignition system:
Ignition timing (B.T.D.C.)
Advanced type
Ignition coil:
Model/Manufacturer
Minimum spark gap
Primary coil resistance
Secondary coil resistance
Spark plug cap:
Type
Model/Manufacturer
Resistance
Charging system:
Type
Nominal output
DC-CDI:
Magneto model/Manufacturer
Standard
Pickup coil resistance
(color code)
Stator coil resistance
(color code)
CDI unit model/Manufacturer
Rectifier/regulator:
Type
Model/Manufacturer
No load regulated voltage (DC)
Capacity (DC)
Withstand voltage
Battery (SXV70ER):
Specific gravity
Manufacture
Type
Ten hour rate amperage
Electric starter system (SXV70ER):
Type
T.P.S. (throttle position sensor)
Model/Manufacturer
Resistance
Y.P.V.S servo motor:
Model/Manufacture
MAINTENANCE SPECIFICATIONS
12 V
5_ at 1,800 r/min
Digital type
F6T535 /MITSUBISHI
3 mm (0.118 in)
0.36 X 0.48 Ω at 20_C (68_F)
5.4 X 7.4 kΩ at 20_C (68_F)
Resin type
T-156/TOKAI DENSO
5 kΩ at 20_C (68_F)
AC magneto
14 V/21 A at 5,000 r/min
F4T36971 /MITSUBISHI
14 V 20 A, 280 W at 5,000 r/min
189 X 231 Ω at 20_C (68_F)
(White/Red – White/Green)
0.36 X 0.44 Ω at 20_C (68_F)
(White – White)
F8T37574 /MITSUBISHI
Short circuit type
SH650D-11/SHINDENGEN
14.1 X 14.9 V
25 A
200 V
1.280
GS
GM18Z-3A
20 A
Bendix type
5FL/MIKUNI
4 X 6 KΩ at 20_C (68_F)
(Green/Yellow – Red/Yellow)
0 X 4 KΩ at 20_C (68_F)
(Green/Yellow – Gray/Black)
8DF/YAMAHA
–137–
SPEC
SXV70/SXV70ER

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sxv70g

Table of Contents