IMPORTANT! Prior to cleaning and sanitizing, the dispenser must be moved
forward at least 4" (102 mm) to allow access to the Bin Lid Cleaning Spout
(Fig . 8 .1) .
CAUTION!
Place the dispenser in Maintenance Mode prior to servicing or
cleaning the ice machine. See Maintenance/Cleaning Mode on
page 8.
Required Supplies
§ (3) x 7 ounce SafeCLEAN™ environmentally-friendly icemaker cleaner
packets
§ Nu-Calgon IMS-II sanitizer
§ Funnel
§ Bucket
Cleaning: Icemaker and Dispenser
1 . Dispense all the ice out of the unit, then see Accessing Internal Components on page 8.
2 . Press and hold maintenance/clean switch until
Mode .
3 . Remove (unscrew) chrome ice dispense chute .
4 . Remove drip tray .
5 . Remove (2) screws located behind the drip tray .
6 . Move front panel and place on top or beside unit .
7 .
Remove plug cap from the end of drain tube and lower tube to drain water into bucket .
8 . After the system has been drained of water replace plug cap in drain tube .
9 . Secure tube in holder .
10 . Remove cap from bin lid cover .
11 . Screw cap onto ice discharge chute .
12 . Mix SafeCLEAN Ice Machine Cleaner, (3) x 7 ounce packets, with three gallons (11 .4 L) of water .
13 . Pour cleaning solution into bin lid access spout until solution reaches the spout neck .
14 . Allow the solution to remain in unit for 15 minutes .
15 . While machine is cleaning, remove top and right side panel to access and clean air-cooled condenser .
16 . Drain system by lowering drain tube into bucket .
17 . Secure drain tube into holder .
18 . Fill one time with potable water and drain with fill tube . Secure drain tube .
Sanitizing: Icemaker and Dispenser
1 . Mix a sanitizing solution of 2 .5 gallons (9 .5 L) of water and 4 ounces (118 ml) of Nu-Calgon* IMS-II
sanitizer .
2 . Pour sanitizing solution into bin lid access spout until solution reaches the spout neck .
3 . Allow the solution to remain in unit for 5 minutes .
4 . Drain system by lowering drain tube .
5 . Secure drain tube into holder .
6 . Fill and drain three times with potable water .
7 .
Place a bucket under the dispense chute and remove cap .
Caution: Some sanitizing solution will remain and drain out when cap is removed . Reposition cap on bin lid spout .
8 . Reinstall front panel, ice dispense chute, and drip tray .
9 . Press and hold maintenance/clean switch to exit Maintenance Mode .
* Calgon is a licensed trade name .
10
Undercounter Dispenser and Icemaker 7UC100A/7UD100A