QUICK PARAMETER REFERENCE, FAULT AND STATUS MESSAGES

Software: V5.2X
Application:
Model:
Serial Number:
Responsible:
Date:
/
/
I. Parameters
Parameter
Function
P000
Parameter Access
READ ONLY PARAMETERS - P002 to P099
P002
Frequency Proportional Value
(P208xP005)
P003
Motor Output Current
P004
DC Link Voltage
P005
Motor Output Frequency
P007
Motor Output Voltage
P008
Heatsink Temperature
(1)
P009
Motor Torque
P014
Last Fault
P023
Software Version
P040
PID Process Variable
(Value % x P528)
REGULATION PARAMETERS - P100 to P199
Ramps
P100
Acceleration Time
P101
Deceleration Time
P102
Ramp 2 Acceleration Time
P103
Ramp 2 Deceleration Time
P104
S Ramp
Frequency Reference
P120
Digital Reference Backup
P121
Keypad Reference
P122
JOG Speed Reference
P124
Multispeed Reference 1
P125
Multispeed Reference 2
P126
Multispeed Reference 3
P127
Multispeed Reference 4
P128
Multispeed Reference 5
P129
Multispeed Reference 6
P130
Multispeed Reference 7
P131
Multispeed Reference 8
.
Adjustable Range
0 to 4 = Read
5 = Alteration
6 to 999 = Read
0 to 6553
0 to 1.5xI
0 to 862
0.00 to 300.0
0 to 600
25 to 110
0.0 to 150.0
00 to 41
x . y z
0 to 6553
0.1 to 999
0.1 to 999
0.1 to 999
0.1 to 999
0 = Inactive
1 = 50 %
2 = 100 %
0 = Inactive
1 = Active
2 = Backup by P121
P133 to P134
0.00 to P134
P133 to P134
P133 to P134
P133 to P134
P133 to P134
P133 to P134
P133 to P134
P133 to P134
P133 to P134
CFW-08 - QUICK PARAMETER REFERENCE
Factory
Setting
nom
10.0
10.0
3.00
5.00
3.00
10.00
20.00
30.00
40.00
50.00
60.00
66.00
User
Unit
Setting
0
-
-
-
-
A
-
V
-
Hz
-
V
-
°C
-
%
-
-
-
-
-
-
5.0
s
s
5.0
s
s
0
-
1
-
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz