8
Press
• Set Value : -50 ~ +50%
(If +20% is entered, the print speed increases by
approximately 20%. If -20% is entered, the print speed
decreases by approximately 20%.)
9
Press the
10
Press the
Changed contents common to all machine types
Stop timer setting of deodorize fan/ drier fan
In the machine setting, we changed stop timer setting of deodorize fan/ drier fan from setting by 10 min. to by 1
min. The range of 0 to 240 has not been changed.
Item
STOP TIME
DEODORIZE
FAN
RENEW
Cleaning intervals setting when AUTO CLEANING/ Print CLEANING is "ON"
In the user type setting, we changed max. value of cleaning intervals setting range when AUTO CLEANING/
Print CLEANING is "ON" from 10000mm to 30000mm. The default value (1000mm) has not been changed.
Recommended maximum value is 10000mm.
In case of setting cleaning intervals beyond 10000mm, nozzle missing may occur depending on the usage
environment. Please be careful.
Function name
ON
AUTO
CLEANING
OFF
ON
Print.
CLEANING
OFF
to change print speed.
key.
key several times to end the setting.
Set value
0 ~ 120 ~ 240min/
CONTINUE
ON / OFF
Set value
INTERVAL
10 ~ 1000 ~ 30000 mm
TYPE
NORMAL / SOFT / HARD
INTERVAL
10 ~ 1000 ~ 30000 mm
TYPE
NORMAL / SOFT / HARD
[ 1 ] MA PS
PR I N T S P EED
[ 1 ]
MA PS
Outline
Setting the time until the rotation of the exhaust
fan is interrupted after the completion of printing.
Switching the current operation of the exhaust
fan.
Sets the auto cleaning of the
print head every completion
of printing.
Sets the auto cleaning of the
print head in printing.
:
1 0 %
< e n t >
Outline
3