For non-conduit installations, plug the detachable
AC line cord into the receptacle on the rear of the
MicroPak Controller. Plug the other end of the line
cord into a properly grounded 120 VAC outlet.
In general, conduit must be used for
>
approved AC installation, however, if na-
tional and local codes permit, the AC power
may be supplied via the factory supplied
line cord.
For installations where it is required to run the AC
input wiring in conduit, perform the following:
1. Ensure the AC line cord is unplugged and
remove the top cover from the controller (see
Figure 9).
2. Remove the AC Inlet Receptacle wiring from
1TB-L1, 1TB-N, and 1TB-Ground (see Figure 1
for AC input wiring locations).
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
! ! ! ! !
Always double check that the control
>
unit is unplugged from its AC outlet before
working with any internal wiring.
7 7 7 7 7
TION
TION
TION
TION
N O T E
N O T E
N O T E
N O T E
N O T E
Figure 1:
Figure 1:
Figure 1:
Figure 1:
Figure 1:
Terminal Block 1 (1TB)
Terminal Block 1 (1TB)
Terminal Block 1 (1TB)
Terminal Block 1 (1TB)
Terminal Block 1 (1TB)
3. Remove the mounting hardware from the AC
Inlet Receptacle and remove it from the rear of the
control unit.
4. Install the Conduit Adapter Plate (supplied)
(76453) in the hole where the AC Inlet Receptacle
was removed (see Figure 2).
5. Install the AC line cord through the Conduit
Adapter Plate using conduit and wire to 1TB as
follows:
Hot/Line
to
Neutral/common
to
Ground
to
6. Reinstall top cover on controller.
Figure 2:
Figure 2:
Figure 2:
Figure 2:
Figure 2:
Installation of Conduit Adapter Plate
Installation of Conduit Adapter Plate
Installation of Conduit Adapter Plate
Installation of Conduit Adapter Plate
Installation of Conduit Adapter Plate
1TB-L1
1TB-N
1TB-Ground
CP-06-01