1. Ensure the AC power, safety ground, low voltage
cable, I/O, and interlock connections are made as
described in the "Installation" section of this manual.
2. Set the 0-10VDC kV setpoint input to its minimum
value (0 volts).
3. Turn the AC Power ON/OFF switch (see Figure
2) to the ON position. When the AC power is on the
green CPU Indicator on the front of the discreet
I/O module will illuminate.
4. Turn the MicroPak ON/OFF switch to the ON
position. The kV and μA displays will come on
along with the yellow MicroPak Power Indicator
located above the switch.
5. Supply a momentary ground connection to the
Ready input shown in Table 1. The yellow High
Voltage Ready Indicator should turn on.
CP-06-01
6. Supply a 24VDC signal to the High Voltage On
input shown in Table 1. The red High Voltage On
Indicator should turn on.
7. Adjust the 0-10VDC kV setpoint input to obtain
the desired value on the kV Meter. Ensure the
over-current setpoint is set above the maximum
expected current, or an overload fault will occur.
The over-current setpoint can be adjusted by
changing the setpoint of R21 if dipswitch SW3-1 is
OFF, or by changing the value of the 0-10VDC
over-current setpoint input (see Table 1) if dipswitch
SW3-1 is ON.
8. To turn high voltage off, remove the 24VDC
signal from the high voltage on input.
9. When finished spraying, turn the AC Power ON/
OFF Switch (see Figure 2) to the OFF position to
prolong the life of the internal fan.