(See Figures 2 & 8)
(See Figures 2 & 8)
(See Figures 2 & 8)
(See Figures 2 & 8)
(See Figures 2 & 8)
AC Power ON/OFF Switch
AC Power ON/OFF Switch
AC Power ON/OFF Switch
AC Power ON/OFF Switch
AC Power ON/OFF Switch
(Figure 2)
(Figure 2)
(Figure 2)
(Figure 2)
(Figure 2)
Turns AC Power to the Evolver MicroPak Controller
on or off.
This switch is located on the rear of the
>
controller.
MicroPak ON/OFF Switch
MicroPak ON/OFF Switch
MicroPak ON/OFF Switch
MicroPak ON/OFF Switch
MicroPak ON/OFF Switch
Turns 24VDC power to the MicroPak control unit
on or off.
MicroPak Power Indicator
MicroPak Power Indicator
MicroPak Power Indicator
MicroPak Power Indicator
MicroPak Power Indicator
Glows yellow when the MicroPak ON/OFF switch
is in the ON position.
μA Adjust Knob
μA Adjust Knob
μA Adjust Knob
μA Adjust Knob
μA Adjust Knob
Used to adjust the over-current setpoint in
combination with the View/Change Setpoint switch
when in local mode.
kV Adjust Knob
kV Adjust Knob
kV Adjust Knob
kV Adjust Knob
kV Adjust Knob
Used to adjust the kV setpoint when in local mode.
Kilovolt Meter Display
Kilovolt Meter Display
Kilovolt Meter Display
Kilovolt Meter Display
Kilovolt Meter Display
Displays voltage in thousands of volts (kilovolts)
present at the applicator electrode.
High Voltage Ready Indicator
High V
High V
oltage Ready Indicator
oltage Ready Indicator
oltage Ready Indicator
High V
High V
oltage Ready Indicator
Glows yellow when High Voltage Ready to the
MicroPak is enabled.
CP-06-01
N O T E
N O T E
N O T E
N O T E
N O T E
MicroPak Controller - Operation
N O T E
N O T E
N O T E
N O T E
N O T E
In local mode, with dipswitch SW3-3
>
OFF, the HV Ready Indicator will not light
until the high voltage is enabled.
High V
High Voltage ON Indicator
High V
oltage ON Indicator
oltage ON Indicator
oltage ON Indicator
High V
High V
oltage ON Indicator
Glows red when high voltage to the applicator is
enabled.
High V
High Voltage Enable/Fault
High V
oltage Enable/Fault
oltage Enable/Fault
oltage Enable/Fault
High V
High V
oltage Enable/Fault
Reset Switch
Reset Switch
Reset Switch
Reset Switch
Reset Switch
Enables high voltage to the applicator when
momentarily moved to the ON position in local
mode with dipswitch SW3-3 off. If dipswitch SW3-
3 is ON high voltage enable is from the remote High
Voltage ON input instead. Also, resets faults when
momentarily moved to the OFF position.
CPU Indicator
CPU Indicator
CPU Indicator
CPU Indicator
CPU Indicator
Glows green whenever power is supplied to the
Discreet I/O Module.
Active Indicator
Active Indicator
Active Indicator
Active Indicator
Active Indicator
Glows green whenever the Discreet I/O Module is
communicating with the MicroPak Control Unit.
Over-Current Fault Indicator
Over-Current Fault Indicator
Over-Current Fault Indicator
Over-Current Fault Indicator
Over-Current Fault Indicator
Glows yellow whenever the current from the
applicator exceeds the over-current setpoint.
View/Change Setpoint Switch
View/Change Setpoint Switch
View/Change Setpoint Switch
View/Change Setpoint Switch
View/Change Setpoint Switch
Displays present current and voltage setpoints
when held in for 1 to 2 seconds. These settings can
be adjusted while the switch is held in as follows:
When in local mode the kV setpoint is adjusted
using the kV adjust knob. When in remote mode
the kV setpoint is adjusted by changing the remote
1 6