Tells where hazards
may occur.
Spray Area /
Spray Area /
Spray Area /
Spray Area /
Spray Area /
High Voltage
High Voltage
High Voltage
High Voltage
High Voltage
Equipment
Equipment
Equipment
Equipment
Equipment
CP-06-01
H A Z A R D
H A Z A R D
H A Z A R D
H A Z A R D
H A Z A R D
Tells what the hazard is.
This is a high voltage device that
can produce electrical arcs capable
of igniting coating materials.
MicroPak Controller - Safety
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
Tells how to avoid the hazard.
Parts being sprayed must be supported on conveyors
or hangers and be grounded. The resistance between
the part and ground must not exceed 1 megohm.
(Reference NFPA- 33.)
A safe distance must be maintained between the
parts being coated and the atomizer bell. A distance
of at least 1 inch for each 10 KV of power supply
output voltage is required at all times.
Parts must be supported so that they will not swing
and reduce the clearance specified above.
All electrically conductive objects in the spray area,
with the exception of those objects required by the
process to be at high voltage, must be grounded.
Unless specifically approved for use in hazardous
locations, the power supply and other electrical
equipment must not be used in Class I, Division 1 or
2 locations.