T T T T T able 2 - Ohmeter Measurements in Ohms from MicroPak
able 2 - Ohmeter Measurements in Ohms from MicroPak
able 2 - Ohmeter Measurements in Ohms from MicroPak
able 2 - Ohmeter Measurements in Ohms from MicroPak
able 2 - Ohmeter Measurements in Ohms from MicroPak
Connector J3 through the Low V
Connector J3 through the Low V
Connector J3 through the Low Voltage Cable to the Cascade
Connector J3 through the Low V
Connector J3 through the Low V
Signal
IFB
From Wire
2 (white)
To Wire
2 (white)
XX
3 (red)
4 (black)
5 (green)
6 (blue)
9 (grn/yel)
10 (gray)
11 (orange)
16 (bare)
* - Meter reading may vary in the megohms range due to capacitance across pins.
CP-06-01
Vct
Vct
DrB
3 (red)
4 (black)
5 (green) 6 (blue)
open ckt. open ckt. open ckt. open ckt. 19K - 21K
XX
0 - 3
0 - 3
XX
0 - 3
XX
Figure 9:
Figure 9:
Figure 9:
Figure 9:
Figure 9:
MicroPak Controller - Maintenance
oltage Cable to the Cascade
oltage Cable to the Cascade
oltage Cable to the Cascade
oltage Cable to the Cascade
DrA
SigGnd
kVFB
9 (grn/yel)
10 (gray)
400K-600K 0 - 3
0 - 3
open ckt.
open ckt.
0 - 3
open ckt.
open ckt.
0 - 3
open ckt.
open ckt.
XX
open ckt.
open ckt.
XX
400K-600K 19K - 21K
XX
Controller Top View
Controller Top View
Controller Top View
Controller Top View
Controller Top View
PLFB
VctRet
11 (orange) 16 (bare)
open ckt.
open ckt.
open ckt.*
open ckt.
open ckt.*
open ckt.
open ckt.*
open ckt.
open ckt.*
open ckt.
400K-600K
open ckt.
XX
open ckt.
XX
2 2
2 2
2 2
2 2
2 2