IBM xSeries 440 Troubleshooting Manual page 50

Eserver type 8687
Hide thumbs Also See for xSeries 440:
Table of Contents

Advertisement

Code
Function
175
System thermal
180
Status display
(light diagnostics
test)
201
System memory
38
xSeries 440:Troubleshooting Guide
Result
Failed
Fan # n
(where n is the number of the failing fan)
Temperature sensed on processor board is out of
range
Failed
Any failure message
Fan light error
Aborted
Test setup error: Corrupt BIOS code in ROM
Test setup error: Corrupt DMI BIOS, information in
BIOS is not as expected
Failed
DIMMs in location DIMM n
(where n is the number of the socket that contains the
failing DIMM)
Description
Action
Replace the indicated
fan.
Call for service.
Call for service.
Replace the fan.
If your server does not
have the latest level
BIOS code installed,
update the BIOS code
to the latest level.
If the problem persists,
call for service.
1. Reseat the failing
DIMM.
2. If the problem
remains, replace the
DIMM.
If the problem
persists, call for
service.