INSTALLATION
Important Do's and Don'ts
1. DO check the incoming mains water pressure. The preferred range of mains
pressure is 2 -3 bar.
2. DO check the flow rate of the incoming cold water main is adequate to meet the
maximum hot and cold water simultaneous demands.
3. DO check that all connections are in accordance with the labelling on the thermal
store.
4. DO check the water level is correctly set in the top up cistern when cold and if
fitted that there is no overflow when the appliance is up to temperature.
5. DO check that the control thermostats switch the immersion heaters off at the
correct set point i.e. approx 75°C.
6. DO insulate any exposed hot water pipework in the BoilerMate CP cupboard.
7. If the ballvalve in the F & E cistern is permanently connected to the mains cold
water supply DO plumb the overflow/warning pipe in a 20mm internal diameter
pipe and ensure it discharges in a conspicuous external position. Use a material
which is suitable for use with heating F & E cisterns in accordance with BS 5449
(such as copper).
8. Once the appliance is filled and commissioned DO leave the electricity switched
on to the appliance to ensure the automatic pump run facility can operate to
prevent the pump sticking.
9. DO ensure that the functioning and control of the system is explained to the
occupant.
10. DON'T place any clothing or other combustible materials against or on top of this
appliance.
The front panel should then be refitted.
SERVICE / CHANGE COMPONENTS
Annual Servicing
No annual servicing of the BoilerMate CP is
necessary.
However, if required, the operation of the
controls and a hot water performance test can
be carried out to prove the appliance is working
satisfactorily and within its specification.
If it is decided to carry out the above tests the
water level in the top cistern should also be
checked and if necessary topped up.

Changing Components

Free of charge replacements for any faulty
components are available from Gledhill during
the in-warranty period on return of the faulty
part (normally 12 months).
After this, spares can be obtained direct from
Gledhill Spares or through any of the larger
plumbers merchants/specialist heating spares
suppliers.
Help and advice is also available from the
Technical Helpline on 01253 474584.
However, all components are readily accessible
and can be changed quickly and easily by the
installer using common plumbing/electrical
practice.
Note: All maintenance work on the
BoilerMate CP appliance must be carried
out by a competent trades person.
Note:
The pump is a Grundfos UPR 15-50 4 wire
pattern and any replacement must be the
same model.
Page 22
Description
1
PHE pump UPR 15-50
2
Plate heat exchanger (24 Plate)
3
Pump isolating valve - outlet (90° valve)
4
Pump isolating valve - inlet
5
Immersion heater 3kW
6
Stat
7
Main PCB controller
8
Sensors
9
Y strainer
10
Flow sensor
11
Scale Inhibitor

SERVICING

Stock Code
GT089
GT017
GT135
GT133
SH003
XB081
XB111A
GT198
XB314
XB095
XB153

SHORT PARTS LIST