SERVICING AND MAINTENANCE
Check pump electrical circuits
LED
Meaning
Diagnosis
Lights green
Normal running
Pump runs according
PWM input
Blinks quick green
Normal stopped
Pump in standby
Blinks red/ green
Abnormal running mode
The pump has stopped
-pump stopped but still
due to external failure
functional
Pump restarts by itself
after the fault has
disappeared
Blinks red
Pump out of function
Pump stopped (blocked)
LED off
No power supply
No voltage on electronics Pump is not connected to
Check plumbing components
CW In line filter
Isolate the CW mains supply at the servicing valve
Open HW taps to relieve the pressure
Undo securing nut ensuring that any remaining water is collected
Remove filter and clean it
The flow regulator can be checked at the same time by removing the upper pipe section.
Thermal store return
Isolate both servicing valves
check valve + return
Drain water from the section between the servicing valves
servicing valve
Remove the bottom pipe section
Check for free movement of the check valve incorporated in the body. Remove and replace if the check
valve sticks.
FAULT FINDING
Cause
Remedy
Normal operation
n/a
n/a
Under voltage U<160 V
Check voltage supply
or
195 V <U< 253 V
Over voltage U>253 V
Pump overheating:
Check water and
temperature inside motor
ambient temperature
too high
Over speed:
Ensure that there is no
the pump rotor is driven
other external flow (other
by an external flow above
pump running) on
the maximum allowed
system
value
Over current:
Check for leakage
the stator winding is in
application on
short circuit due to water
application
Overload of motor:
Check installation water
friction due to particles
quality, clean system if
and/or impeller blocked
debris
with debris
Blockage:
Check for blockage.
the pumps is fully
Turn ON/OFF to reset
blocked due to debris in
the pump by unplugging
system
the power supply
If the pumps still blinking
Faulty electronic module
red after a power reset
and/or faulty motor
then replace the pump
Check cable connection
power supply
LED is damaged
Check if pump is running
Electronics are damaged
Replace pump