Verifying Interface Connectivity - Cisco MDS 9216 Configuration Manual

Mds 9000 series san volume controller
Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

Verifying Interface Connectivity

Verifying Interface Connectivity
This section lists the show commands that help verify the SVC interface state and the N-port association
with the SVC interface.
Example 2-1
switch# show interface svc 2/1
svc2/1 is up
Example 2-2
switch# show svc session svc 2/1
svc2/1:
Example 2-3
switch# show fcns database
VSAN 1:
--------------------------------------------------------------------------
FCID
--------------------------------------------------------------------------
0xe80000
0xe80003
0xe80200
0xe80300
Total number of entries = 4
VSAN 2:
--------------------------------------------------------------------------
FCID
--------------------------------------------------------------------------
0xe80000
0xe80001
Total number of entries = 2
VSAN 3:
--------------------------------------------------------------------------
FCID
Cisco MDS 9000 Family SAN Volume Controller Configuration Guide
2-8
Displays Information for A Specified SVC Interface
Node WWN is 2e:ab:00:05:30:00:1a:e0
Fabric WWN is 20:01:00:05:30:00:1a:de
Target N-port WWN is 2e:a5:00:05:30:00:1a:e0, vsan is 1, FCID is 0xe80003
Initiator N-port WWN is 21:2e:00:05:30:00:00:21, vsan is 3, FCID is 0xea0004
Mgmt N-port WWN is 2f:af:00:05:30:00:1a:e0, vsan is 2, FCID is 0xe80000
5 minutes input rate 2392 bits/sec, 299 bytes/sec, 0 frames/sec
5 minutes output rate 2240 bits/sec, 280 bytes/sec, 0 frames/sec
272 frames input, 89764 bytes
0 discards, 0 errors
232 frames output, 84176 bytes
0 discards, 0 errors
Displays N-port Connections for a Specified SVC Interface
Target N-port WWN is 2e:a5:00:05:30:00:1a:e0, vsan is 1, FCID is 0xe80003
pWWN 21:01:00:e0:8b:31:20:31, nWWN 20:01:00:e0:8b:31:20:31, FCID 0xe80200
pWWN 21:00:00:e0:8b:11:29:31, nWWN 20:00:00:e0:8b:11:29:31, FCID 0xe80300
Initiator N-port WWN is 21:2e:00:05:30:00:00:21, vsan is 3, FCID is 0xea0004
pWWN 50:05:07:63:00:c8:9c:f9, nWWN 50:05:07:63:00:c0:9c:f9, FCID 0xea0000
pWWN 50:05:07:63:00:c8:9c:fa, nWWN 50:05:07:63:00:c0:9c:fa, FCID 0xea0001
Mgmt N-port WWN is 2f:af:00:05:30:00:1a:e0, vsan is 2, FCID is 0xe80000
pWWN 2f:b9:00:05:30:00:1a:e0, nWWN 2f:b7:00:05:30:00:1a:e0, FCID 0xe80002
pWWN 2f:ba:00:05:30:00:1a:e0, nWWN 2e:b3:00:05:30:00:1a:e0, FCID 0xe80003
pWWN 2f:b8:00:05:30:00:1a:e0, nWWN 2e:ac:00:05:30:00:1a:e0, FCID 0xe80001
Displays the FCNS Database
TYPE
PWWN
N
2e:a8:00:05:30:00:1a:e0 (Cisco)
N
2e:a5:00:05:30:00:1a:e0 (Cisco)
N
21:01:00:e0:8b:31:20:31 (QLogic)
N
21:00:00:e0:8b:11:29:31 (QLogic)
TYPE
PWWN
N
2f:af:00:05:30:00:1a:e0 (Cisco)
N
2f:b8:00:05:30:00:1a:e0 (Cisco)
TYPE
PWWN
(VENDOR)
FC4-TYPE:FEATURE
scsi-fcp:target svc
scsi-fcp:target svc
scsi-fcp:init
scsi-fcp:init
(VENDOR)
FC4-TYPE:FEATURE
scsi-fcp:both svc
scsi-fcp:both svc
(VENDOR)
FC4-TYPE:FEATURE
78-16119-01, Cisco MDS SAN-OS Release 1.3
Chapter 2
Getting Started

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series

Table of Contents